General information
PSCAN-D-1D-D2 Division 2 Barcode Reader
1
Subject to modifications
www.pepperl-fuchs.us
USA: +1 330 486 0002
Singapore: +65 6779 9091
Copyright Fuchs
Germany: +49 621 776 2222
Copyright © 2017 by Fuchs GmbH
All rights reserved
The publisher reserves the right to alter the information and data
contained in this manual without prior notice. Unless otherwise
indicated, the company names as well as other names and data used
in the examples are purely fictitious. The publisher may have registered
patents or pending patent applications for subject matter covered in the
manual. This manual does not give you license to these patents.
LIMITED WARRANTY:
NO WARRANTY IS PROVIDED FOR THE ACCURACY OF THE INFORMATION
CONTAINED IN THIS MANUAL. AS MISTAKES CANNOT BE ENTIRELY AVOIDED
DESPITE TAKING THE GREATEST OF CARE, WE WOULD BE GRATEFUL TO
RECEIVE INFORMATION ABOUT ANY ERRORS YOU MAY DISCOVER. THE
PUBLISHER DISCLAIMS ALL LEGAL RESPONSIBILITY OR LIABILITY FOR
ERRORS AS WELL AS FOR SUBSEQUENT DAMAGES AND CLAIMS.
MANUFACTURER:
PEPPERL-FUCHS, INC.
1600 ENTERPRISE PKWY
TWINSBURG, OH 44087USA
www.pepperl-fuchs.us
Tel. 330-486-0002
Fax 330-963-5827
E-Mail: [email protected]
Safety
General safety instructions
•
The plant owner is responsible for its planning, installation,
commissioning, operation, maintenance, and disassembly.
•
Installation and commissioning of all devices must be performed by
a trained professional only.
•
Protection of operating personnel and the system is not ensured if
the product is not used in accordance with its intended purpose.
•
Laws and regulations applicable to the usage or the intended
purpose must be observed.
•
The devices are only approved for appropriate and intended use.
Ignoring these instructions will void any warranty and absolve the
manufacturer from any liability.
•
The Declaration of Conformity, Certificate of Compliance, Statement
of Conformity, EC type-examination certificate and data sheets are
an integral part of this document.
•
The data sheet contains the electrical data of the Declaration
of Conformity, the Certificate of Compliance, and the EC-type-
examination certificate.
•
The documents mentioned are available from
http://www.pepperl-fuchs.com or your local Fuchs
representative.
Delivery, transport, and storage
•
Check the packaging and contents for damage.
•
Check if you have received every item and if the items received are
the ones you ordered.
•
Keep the original packaging. Always store and transport the device
in the original packaging.
•
Always store the device in a clean and dry environment. The
permitted storage temperature (see datasheet) must be considered.
PSCAN-D-1* intended use
The PSCAN-D-1D-D2 EX barcode reader can be used in Class I/Div. 2,
Class II/Div. 2, and Class III/Div.2 hazardous areas. The barcode reader
is able to read all standard 1-D code families. An audible beep will be
heard once a successful scan is completed. Bidirectional communication
between barcode reader and host is also possible.
Supply and communication of the barcode reader is made by a
nonincendive barrier that is required for Div. 2 installation. The devices
are only approved for appropriate and intended use. Ignoring these
instructions will void any warranty and absolve the manufacturer from
any liability.
Installation and commissioning
The installation instructions in accordance with IEC/EN 60079-14 must
be observed. If devices have already been operated in general electrical
systems, they may no longer be installed in electrical systems used in
combination with hazardous areas. The respective peak values of the
field device and the associated apparatus with regard to explosion
protection should be considered when connecting nonincendive field
devices.
Technical data
Hazardous location label
Data for Use in Conjunction with Hazardous Areas
Voltage (U)
10 VDC
Current (I)
500 mA
Capacitance (C)
250 µF
Inductance (L)
75 µH
Operating Temperature
Ambient temperature
-
10
º
C to 50
º
C (14
ºF
to 122
º
F)