PSCAN-D-1D-D2 Division 2 Barcode Reader
24
Subject to modifications
www.pepperl-fuchs.us
USA: +1 330 486 0002
Singapore: +65 6779 9091
Copyright Fuchs
Germany: +49 621 776 2222
Enter Configuration
Exit and Save Configuration
Ì$+;Î
DATA FORMAT
Ì$-?Î
75
FIELD ADJUSTMENT
disable field adjustment
ÌEF0[Î
Field adjustment allows a number of characters
n
, to be added to or subtracted from the
barcode read. The adjustment can be different for each enabled code type. To define the field
adjustment:
Read the enable field adjustment code:
enable field adjustment
ÌEF+Î
Select the code type from the Code Identifier Table in Appendix
B
.
Select the type of adjustment to perform:
right addition
Ì01Î
left addition
right deletion
Ì12Î
Ì23Î
left deletion
Ì34Î
Read a number in the range
01 - 32 from the Hex/Numeric Table to define how many
characters to add or delete:
Conditions:
Adjustment is only performed on the barcode data, the Code Identifier and Code Length
Transmission fields are not modified by the field adjustment parameter.
If the field setting would subtract more characters than exist in the barcode, the subtraction
will take place only to code length 0.
You can set up to a maximum of 10 different field adjustments on the same barcode family
or on different barcode families.
Example: To add 4 characters to the right of Standard Code 39 Codes:
enable field adjustment
Code 39
right addition
Read
ÌEF+Î
+
ÌVWÎ
+
Ì01Î
+
04
, page 75.