![background image](http://html.mh-extra.com/html/pepperl-fuchs/pscan-d-1d-d2/pscan-d-1d-d2_installation-and-operation-manual_1527626021.webp)
PSCAN-D-1D-D2 Division 2 Barcode Reader
19
Subject to modifications
www.pepperl-fuchs.us
USA: +1 330 486 0002
Singapore: +65 6779 9091
Copyright Fuchs
Germany: +49 621 776 2222
Data format
•
Code identifier
•
Custom code identifier
•
Header
•
Terminator
•
Special keys
•
Field adjustment
•
Field adjustment character
•
Code length Tx
•
Character replacement
Default reading parameter
Parameter
Default
Flash mode
On 1 second, off 0.6 seconds
Reads per cycle
1
Safety time
0.5 seconds
Beeper intensity
High intensity
Beeper tone
Ton 2
Beeper type
Monotone
Beeper length
Short
Good read spot duration
Medium
Aiming system
Disabled
Default decoding parameters
Parameter
Default
Ink spread
Enabled
Overflow control
Enabled
Interdigit control
Enabled
Decoding safety
One read
Puzzle solver
Disabled
Default code selection
Parameter
Default
EAN /UPC - family
EAN 8/EAN 13 / UPC A/UPC E
Check digit control
No conversion
2/5 family
Interleaved 2/5
Check digit control and transmission
Variable code length: 4-55 characters
Code 39 family
Standard Code 39
No check digit control
Variable code length: 1-99 characters
Code 128 family
Code 128
Check digit control without transmission
Add GS before code = disabled
Code 93
Disabled
Codabar family
Disabled
MSI
Disabled
Code 11
Disabled
Code 16K
Disabled
Code 49
Disabled
GS1 DATABAR codes
Disabled
Default advanced formatting
Parameter
Default
Concatenation
Disabled
Advanced formatting
No advanced formatting enabled
To change the default values
1. Read the "Enter Configuration" code once.
2. Read configuration codes from the desired groups or follow the
procedure given for this code group.
3. When desired you can change further configuration codes directly.
4. Read the "Exit and Save Configuration" code once.