Power Supply PS1000-D2-24.40.RM
EMC
20
21
-1
1
17
11
EMC
The redundancy module is suitable for applications in industrial environment as well
as in residential, commercial and light industry environment without any restrictions.
A detailed EMC report is available on request.
EMC Immunity
According to generic standards: EN 61000-6-1 and EN 61000-6-2
Electrostatic discharge
EN 61000-4-2
Contact discharge
Air discharge
8kV
15kV
Criterion A
Criterion A
Electromagnetic RF field
EN 61000-4-3
80MHz-2.7GHz
20V/m
Criterion A
Fast transients (Burst)
EN 61000-4-4
Input lines
Output lines
2kV
2kV
Criterion A
Criterion A
Surge voltage on input lines
EN 61000-4-5
+
→
–
+ / –
→
Chassis ground
500V
1kV
Criterion A
Criterion A
Surge voltage on output lines
EN 61000-4-5
+
→
–
+ / –
→
Chassis ground
500V
1kV
Criterion A
Criterion A
Conducted disturbance
EN 61000-4-6
0.15-80MHz
20V
Criterion A
Power-frequency magnetic field
1
EN 61000-4-8
50Hz
30A/m
Criterion A
1
A test is not applicable according to EN 61000-6-2, since the device does not contain components susceptible to magnetic fields,
e.g. hall elements, electrodynamic microphones, etc.
Criterion A
Redundancy module shows normal operation behavior within the defined limits.
EMC Emission
According to generic standards: EN 61000-6-3 and EN 61000-6-4
Conducted emission
IEC/CISPR 16-1-2,
IEC/CISPR 16-2-1
Limits for DC power port according
EN 61000-6-3 fulfilled
1 2
Radiated emission
EN 55011, EN 55032
Class B
This device complies with FCC Part 15 rules.
Operation is subjected to following two conditions: (1) this device may not cause harmful interference, and (2)
this device must accept any interference received, including interference that may cause undesired operation.
1
For information only, not mandatory for EN 61000-6-3.
2
Provided, that power sources connected on the inputs fulfill the requirements too.
Switching frequency
The internal auxiliary supply is generated with a boost converter.
The switching frequency varies from 140kHz to 500kHz depending on the input
voltage.