20
21
-1
1
10
Power Supply PS1000-D2-24.40.RM
Installation Instructions
A PE (ground) connection is not required. However, connecting the chassis ground terminal
to ground can be beneficial to gain a high EMI immunity.
The device is designed for convection cooling and does not require an external fan.
Do not obstruct airflow and do not cover ventilation grid!
The device is designed for altitudes up to 6000m (19685ft). See additional requirements
in the product datasheet for use above 2000m (6560ft).
Keep the following minimum installation clearances: 40mm on top, 20mm on the bottom,
5mm left and right side. Increase the 5mm to 15mm in case the adjacent device is a heat
source. When the device is permanently loaded with less than 50%, the 5mm can be reduced
to zero. Under special circumstances clearances can be reduced. See details in the product
datasheet.
The maximum surrounding air temperature is +70°C (+158°F). The operational temperature
is the same as the ambient or surrounding air temperature and is defined 2cm below
the device.
The device is designed to operate in areas between 5% and 95% relative humidity.