background image

PMI360DV-F130-IU2E2-V15

Troubleshooting

 201

5-0

6

21

9

Troubleshooting

9.1

Faults when programming the outputs

If unexpected situations occur when the outputs of the inductive angular positioning system are 

programmed, refer to the table below for possible causes and instructions for rectifying the 

problem.

State

Possible cause

Action

The buttons do not unlock. 

Buttons S1 and S2 not 

pressed long enough.

Press the buttons 

 3 seconds 

to unlock the buttons (see 

chapter 6.1).

Sensor cannot be moved in 

programming mode. The 

"Power/Error" LED lights up 

red when a button is pressed.

Keylock is activated.

Unlock the buttons (see 

chapter 6.1 or )

Sensor cannot be moved in 

programming mode (relevant 

yellow LED does not flash 

when a button is pressed).

Button not pressed long 

enough.

Press the button for 

programming the output 

 2 s.

Sensor cannot be moved in 

programming mode 

("Power/Error" LED lights up 

red).

No actuator available or own 

actuator mounted too far away 

from the surface of the sensor.

Mount actuator according to 

specifications (see chapter 

5.2).

"Power/Error" LED lights up 

red during programming.

Actuator lost during the 

parameterization process or 

distance between actuator 

and surface of sensor too 

great (own actuator).

Make sure that the 

concentricity and adjustment 

of own actuator does not 

result in a loss of the actuator 

(see chapter 5.2).

LED stops flashing during the 

programming process.

Timeout while programming 

the output (1 minute after the 

last input).

Move sensor again in 

programming mode (see 

chapter 6.1 or )

After programming, the 

function of the output/outputs 

remains unchanged.

Programming process not 

completed within the time 

frame (1 minute) or incorrect 

button pressed during 

programming.

Complete the programming 

process by pressing the 

corresponding button for the 

output a third time within the 

time frame (see chapter 6.1 o

)

A yellow LED flashes and the 

"Power/Error" LED flashes red 

at the same time.

The button assigned to the 

flashing yellow LED is stuck.

Remove any dirt or foreign 

objects that are causing the 

key to stick.

Содержание PMI360DV-F130-IU2E2-V15

Страница 1: ...PMI360DV F130 IU2E2 V15 Inductive angle positioning system FACTORY AUTOMATION MANUAL...

Страница 2: ...of Delivery for Products and Services of the Electrical Indus try published by the Central Association of the Electrical Industry Zentralverband Elektrotechnik und Elektroindustrie ZVEI e V in its mos...

Страница 3: ...cessories 10 4 4 1 Connecting cable 10 4 4 2 Actuator 10 5 Installation 11 5 1 Note on safety 11 5 2 Mounting 11 5 3 Electrical connection 13 6 Commissioning 14 6 1 Programming the switching outputs 1...

Страница 4: ...4 PMI360DV F130 IU2E2 V15 9 Troubleshooting 21 9 1 Faults when programming the outputs 21 9 2 Faults during operation 22 10 Disposal 23...

Страница 5: ...gy on a worldwide scale Symbols used The following symbols are used in this manual Handling instructions You will find handling instructions beside this symbol Contact If you have any questions about...

Страница 6: ...developed and manufactured under observance of the applicable European standards and guidelines The product manufacturer Pepperl Fuchs GmbH D 68307 Mannheim has a certified quality assurance system t...

Страница 7: ...e performed by a trained professional only User modification and or repair are dangerous and will void the warranty and exclude the manufacturer from any liability If serious faults occur stop using t...

Страница 8: ...s an analog output for the indication of angular positions For high resistance loads 3 3 k the angular position will output a voltage value 0 10 V DC and for low resistance loads 400 a current value 4...

Страница 9: ...e the start and end points of the analog output and the outer S1 and S2 buttons are used to configure the start and end of the detection zone of the two switching outputs on the sensor The S1 S2 and I...

Страница 10: ...at may be used in electrically noisy installation environments 4 4 2 Actuator The BT F130 A actuator is designed for mounting directly on the drive shaft or a servodrive Figure Material Length Order d...

Страница 11: ...ctuator The actuator must not make physical contact or scratch the sensors surface when moving Using a different actuating element You may use a different actuator instead of the BT F130 A actuator pr...

Страница 12: ...inner surface E Sensor F Insert the shaft until actuator C and the sensitive surface on sensor D overlap as far as possible Dimension Value t 2 mm w 7 5 mm d1 Depending on the drive shaft material S23...

Страница 13: ...4 Check that the wires are connected correctly before connecting the cordset to the sensor On Pepperl Fuchs cordsets the wire colors are assigned to the connecting pins in the connector according to...

Страница 14: ...he device is ready for you to teach in the signaling zone end point 5 Move the actuator to the position that you wish to define as the signaling zone end point The rotation direction of the actuator i...

Страница 15: ...The yellow I U LED lights up for 2 seconds and then starts to flash again This indicates that the device is ready for you to teach in the end point of the analog ramp 4 Move the actuator to the posit...

Страница 16: ...If you intend to program an angle segment of exactly 360 for the analog output you can make use of the restriction that prevents the angle segment from exceeding 360 In the second step of the angle se...

Страница 17: ...tion of the second switching point of switching output S2 example 310 6 Start position of analog output S3 example 20 7 End position of analog output S3 example 110 8 Angular range outside of analog m...

Страница 18: ...ry The start and end points of the analog measuring range can be defined by programming each relevant angular position the only restriction being that the analog measurement range must fall between 45...

Страница 19: ...ctuator leaves the detection range of the angular positioning system e g actuator is removed the function of the output depends on whether the analog output assumes the function of a voltage or a curr...

Страница 20: ...he associated yellow LED starts to flash slowly after 2 seconds 2 Continue to hold the sensor button The LED begins to flash more quickly after an additional 10 seconds 3 Then release the button withi...

Страница 21: ...actuator mounted too far away from the surface of the sensor Mount actuator according to specifications see chapter 5 2 Power Error LED lights up red during programming Actuator lost during the param...

Страница 22: ...3 6 mA No actuator in the detection area of the sensor or unreliable detection of the actuator Check that the actuator used is mounted correctly or install an actuator with appropriate dimensions at...

Страница 23: ...osal Electronic waste is hazardous waste When disposing of the equipment observe the current statutory requirements in the respective country of use as well as local regulations The device does not co...

Страница 24: ...hs GmbH 68307 Mannheim Germany Tel 49 621 776 0 E mail info de pepperl fuchs com USA Headquarters Pepperl Fuchs Inc Twinsburg Ohio 44087 USA Tel 1 330 4253555 E mail sales us pepperl fuchs com Asia Pa...