201
5-0
6
12
Installation
Actuator (C) can be placed on the insulating ring made from non-conductive material
(B) or inserted in this ring.
Dimensions when using a different actuating element
A
Drive shaft
B
Insulation ring made from non-conductive material
C
Separate actuator (L
mm)
D
Sensitive surface on the sensors (black, cylindrical inner surface)
E
Sensor
F
Insert the shaft until actuator C and the sensitive surface on sensor D overlap as
far as possible.
Dimension
Value
t
2 mm
w
7.5 mm
d1
Depending on the drive shaft material
AR (previously St37-2): max. 19 mm
Stainless steel 1.4435 / AISI 316L (V4A): max. 21 mm
Stainless steel 1.4305 / AISI 303 (V2A): max. 23 mm
d2
Select so that the distance between the edges of the actuator and the
sensitive surface on the sensor is 1 ... 2 mm.
d3
41.5 mm
Actuator material
Construction steel such as AR (previously St37-2)
w
A
C
D
E
B
F
t
d1
d2
L
d3