Pepperl+Fuchs PMI360DV-F130-IU2E2-V15 Скачать руководство пользователя страница 14

 201

5-0

6

14

PMI360DV-F130-IU2E2-V15

Commissioning

6

Commissioning

6.1

Programming the switching outputs

2 switching zones with a zone width of 5

°

 are preset at the factory. The switching zones lie 

between the angle settings 120

°

... 125 

°

 (S1) and 240

°

 ... 245

°

 (S2). You can modify the 

position and width of these switching zones by programming them accordingly. The start and 

end points of a switching zone can be defined at any position. The smallest angle range of a 

switching zone can be 5

°

 and the largest angle range of a switching zone 360

°

.

Program switching output 1 (S1) as follows:

Programming switching output S1

1. Make sure that the sensor is mounted correctly and securely, and check that an actuator with 

the specified dimensions is positioned at the correct distance from the surface of the sensor. 

See chapter 5.2

2. Unlock the keyboard, if locked. See "Unlocking the buttons" on page 14
3. Press the S1 button for 

 2 s.

 The flashing yellow LED indicates that the device is ready for you to teach in the 

signaling zone start point.

4. Move the actuator to the position that you wish to define as the start point of the signaling 

zone. Press the S1 button again.

 The yellow S1 LED lights up for 2 seconds and then starts to flash again. This indicates 

that the device is ready for you to teach in the signaling zone end point.

5. Move the actuator to the position that you wish to define as the signaling zone end point. 

The rotation direction of the actuator is decisive here. At the end of programming, 

the area covered by the actuator will be the angle range in which the switching 

output is active.

6. Briefly press the S1 button.

 The setting is then stored in the non-volatile memory of the sensor. The yellow LED then 

lights up permanently to indicate that programming was successful.

Note!
Unlocking the buttons

If the keylock is active, it must first be deactivated. The sensor indicates that the keylock is 

active by changing the color of the "Power/Error" LED to red when a button is pressed. To 

unlock the buttons, press and hold the S1 and S2 buttons simultaneously for 3 seconds. The 

color of the "Power/Error" LED changes to green. The buttons are no longer locked.

Note!

If the actuator does not move between the time the signaling zone start and end points are 

programmed, the smallest possible signaling zone is programmed with a width of 5

°

. The 

signaling zone start point is then set at the programmed position.

Note!

If interrupted for more than 1 minute, the programming process is terminated. The sensor 

continues operating with unchanged values.

Note!

The programming process is terminated if any button is pressed other than the correct button. 

The sensor continues operating with unchanged values.

Содержание PMI360DV-F130-IU2E2-V15

Страница 1: ...PMI360DV F130 IU2E2 V15 Inductive angle positioning system FACTORY AUTOMATION MANUAL...

Страница 2: ...of Delivery for Products and Services of the Electrical Indus try published by the Central Association of the Electrical Industry Zentralverband Elektrotechnik und Elektroindustrie ZVEI e V in its mos...

Страница 3: ...cessories 10 4 4 1 Connecting cable 10 4 4 2 Actuator 10 5 Installation 11 5 1 Note on safety 11 5 2 Mounting 11 5 3 Electrical connection 13 6 Commissioning 14 6 1 Programming the switching outputs 1...

Страница 4: ...4 PMI360DV F130 IU2E2 V15 9 Troubleshooting 21 9 1 Faults when programming the outputs 21 9 2 Faults during operation 22 10 Disposal 23...

Страница 5: ...gy on a worldwide scale Symbols used The following symbols are used in this manual Handling instructions You will find handling instructions beside this symbol Contact If you have any questions about...

Страница 6: ...developed and manufactured under observance of the applicable European standards and guidelines The product manufacturer Pepperl Fuchs GmbH D 68307 Mannheim has a certified quality assurance system t...

Страница 7: ...e performed by a trained professional only User modification and or repair are dangerous and will void the warranty and exclude the manufacturer from any liability If serious faults occur stop using t...

Страница 8: ...s an analog output for the indication of angular positions For high resistance loads 3 3 k the angular position will output a voltage value 0 10 V DC and for low resistance loads 400 a current value 4...

Страница 9: ...e the start and end points of the analog output and the outer S1 and S2 buttons are used to configure the start and end of the detection zone of the two switching outputs on the sensor The S1 S2 and I...

Страница 10: ...at may be used in electrically noisy installation environments 4 4 2 Actuator The BT F130 A actuator is designed for mounting directly on the drive shaft or a servodrive Figure Material Length Order d...

Страница 11: ...ctuator The actuator must not make physical contact or scratch the sensors surface when moving Using a different actuating element You may use a different actuator instead of the BT F130 A actuator pr...

Страница 12: ...inner surface E Sensor F Insert the shaft until actuator C and the sensitive surface on sensor D overlap as far as possible Dimension Value t 2 mm w 7 5 mm d1 Depending on the drive shaft material S23...

Страница 13: ...4 Check that the wires are connected correctly before connecting the cordset to the sensor On Pepperl Fuchs cordsets the wire colors are assigned to the connecting pins in the connector according to...

Страница 14: ...he device is ready for you to teach in the signaling zone end point 5 Move the actuator to the position that you wish to define as the signaling zone end point The rotation direction of the actuator i...

Страница 15: ...The yellow I U LED lights up for 2 seconds and then starts to flash again This indicates that the device is ready for you to teach in the end point of the analog ramp 4 Move the actuator to the posit...

Страница 16: ...If you intend to program an angle segment of exactly 360 for the analog output you can make use of the restriction that prevents the angle segment from exceeding 360 In the second step of the angle se...

Страница 17: ...tion of the second switching point of switching output S2 example 310 6 Start position of analog output S3 example 20 7 End position of analog output S3 example 110 8 Angular range outside of analog m...

Страница 18: ...ry The start and end points of the analog measuring range can be defined by programming each relevant angular position the only restriction being that the analog measurement range must fall between 45...

Страница 19: ...ctuator leaves the detection range of the angular positioning system e g actuator is removed the function of the output depends on whether the analog output assumes the function of a voltage or a curr...

Страница 20: ...he associated yellow LED starts to flash slowly after 2 seconds 2 Continue to hold the sensor button The LED begins to flash more quickly after an additional 10 seconds 3 Then release the button withi...

Страница 21: ...actuator mounted too far away from the surface of the sensor Mount actuator according to specifications see chapter 5 2 Power Error LED lights up red during programming Actuator lost during the param...

Страница 22: ...3 6 mA No actuator in the detection area of the sensor or unreliable detection of the actuator Check that the actuator used is mounted correctly or install an actuator with appropriate dimensions at...

Страница 23: ...osal Electronic waste is hazardous waste When disposing of the equipment observe the current statutory requirements in the respective country of use as well as local regulations The device does not co...

Страница 24: ...hs GmbH 68307 Mannheim Germany Tel 49 621 776 0 E mail info de pepperl fuchs com USA Headquarters Pepperl Fuchs Inc Twinsburg Ohio 44087 USA Tel 1 330 4253555 E mail sales us pepperl fuchs com Asia Pa...

Отзывы: