201
5-0
6
14
Commissioning
6
Commissioning
6.1
Programming the switching outputs
2 switching zones with a zone width of 5
°
are preset at the factory. The switching zones lie
between the angle settings 120
°
... 125
°
(S1) and 240
°
... 245
°
(S2). You can modify the
position and width of these switching zones by programming them accordingly. The start and
end points of a switching zone can be defined at any position. The smallest angle range of a
switching zone can be 5
°
and the largest angle range of a switching zone 360
°
.
Program switching output 1 (S1) as follows:
Programming switching output S1
1. Make sure that the sensor is mounted correctly and securely, and check that an actuator with
the specified dimensions is positioned at the correct distance from the surface of the sensor.
See chapter 5.2
2. Unlock the keyboard, if locked. See "Unlocking the buttons" on page 14
3. Press the S1 button for
2 s.
The flashing yellow LED indicates that the device is ready for you to teach in the
signaling zone start point.
4. Move the actuator to the position that you wish to define as the start point of the signaling
zone. Press the S1 button again.
The yellow S1 LED lights up for 2 seconds and then starts to flash again. This indicates
that the device is ready for you to teach in the signaling zone end point.
5. Move the actuator to the position that you wish to define as the signaling zone end point.
The rotation direction of the actuator is decisive here. At the end of programming,
the area covered by the actuator will be the angle range in which the switching
output is active.
6. Briefly press the S1 button.
The setting is then stored in the non-volatile memory of the sensor. The yellow LED then
lights up permanently to indicate that programming was successful.
Note!
Unlocking the buttons
If the keylock is active, it must first be deactivated. The sensor indicates that the keylock is
active by changing the color of the "Power/Error" LED to red when a button is pressed. To
unlock the buttons, press and hold the S1 and S2 buttons simultaneously for 3 seconds. The
color of the "Power/Error" LED changes to green. The buttons are no longer locked.
Note!
If the actuator does not move between the time the signaling zone start and end points are
programmed, the smallest possible signaling zone is programmed with a width of 5
°
. The
signaling zone start point is then set at the programmed position.
Note!
If interrupted for more than 1 minute, the programming process is terminated. The sensor
continues operating with unchanged values.
Note!
The programming process is terminated if any button is pressed other than the correct button.
The sensor continues operating with unchanged values.