2015-01
9
Connecting and Wiring Diagrams
6.1.1
Network Connection Ethernet (X1)
VisuNet RM and VisuNet PC
(10/100 BASE TX Ethernet cable: DATL-CAT71-8-2, recommendation for cable see
chap.10.3.1)
Version 1
: with component: Box-A10 (max over all distance: max. 90m over all)
Connection
instruction Box-A10 see chap. 9.2
orange
each
twisted
terminal compartment X1 Ex e
Insert shield
into cable
gland
white
green
orange
blue
white
brown
white
RJ 45
safe area
**Terminal compartment for
connection to hub, switch,
repeater or router
Box-A10
R
J
4
5
Cable:
DATL-CAT71-8-2
white
PC
Switch
Router ...
Junction box
DIN-rail
The cable shield has to be connected in the cable gland. (see chap. 10.4.2)
Version 2
: with component: Cable DATL-C/TP-1-1RJ45 (distance: max. 90m)
orange
each
twisted
terminal compartmemt
X1 Ex e
white
green
white
orange
blau
white
brown
white
RJ 45
safe area
DATL-C7TP-1-1RJ45
Insert shield
into cable
gland
**Terminal compartment for
connection to hub, switch,
repeater or router
PC
Switch
Router ...
The cable shield has to be connected in the cable gland. (see chap. 10.4.2)
Содержание PC419
Страница 49: ...2015 01 45 Accessories VisuNet RM and VisuNet PC Holder for the Barcode Reader at the Case AG1...
Страница 77: ...2015 01 A Notes...
Страница 78: ...2015 01 B Notes...
Страница 79: ...2015 01 C Notes...
Страница 80: ...2015 01 D Notes 266858 TDOCT 3675AENG 01 2015...