Product Description
2.3
Displays and Operating Elements
The seven LEDs mounted on the lighting unit can be used to read different information.
Figure 2.2
Lighting unit of the OIT system
Item
Designation
Function
1
Code OK
Reading successful. Flashes for approx. 5 seconds
when the parameters have been applied successfully.
2
Error
Lights up red when a read error occurs.
3
Trigger
Lights up yellow when a connected trigger sensor is
activated.
4
Stability of image
information
Lights up red if the captured image could be read but
increasing deterioration of the ambient conditions may
result in a reading error. This can occur, for example, in
the following situations: if the camera image is too
light/dark, if the contrast is too low, if there are too many
structures in the image, if the code sheet is just within
the read distance, or if the code sheet is only just within
the image area.
5
Ready for operation
The LED flashes for approx. 30 seconds while it is
starting up. During this time, no network connection can
be established with the OIT. The LED lights up as soon
as the OIT is ready for operation.
6
Power
Lights up green when the OIT system is supplied with
power.
7
Lighting control
Lights up red when infrared illumination is active.
1
2
3
4
5
6
7