Mounting and Installation
3.2
Mounting the OIT System
3.2.1
Operating Distance
The operating distance is the distance from the glass pane of the OIT system to the code
sheet. The OIT system is set to a reading distance of
380 mm
by default.
Figure 3.3
Operating distance (top view)
Warning!
Danger to life due to defective mounting
Errors during mounting can cause life-threatening injuries and significant property damage.
Ensure the installation is performed only by sufficiently trained and qualified personnel.
Trained and qualified personnel have relevant experience in this area. They know and
understand the rules and standards for the components and systems.
Prior to mounting, ensure that the plant is de-energized.
The device is relatively heavy. Handle the device carefully.
Note!
Avoid bright areas in the background when mounting the code plate. The code plate must be
brighter than the background. If this is not the case, reading may be impossible.
300 ...
450 mm
170 mm
470 ...
620 mm
OIT500