Error messages in basic read/write operating mode
The status word consists of 2 bytes which follow the command header in the re-
sponse. If there is no error, 00 will be transmitted. A status word other than 00 indi-
cates that one of the error conditions described below has occurred.
Error messages / Status:
Hex-Value
Description
00
No error
01
Command not defined
02
Read head not connected or not ready
03
No code carrier or data carrier connected, or unable to transmit
data.
04
Write error
05
EPROM error
06
Check sum error (serial interface)
07
RAM error
08
Check sum error (data carrier)
09
Address or data volume outside admissible range
0A
Unable to communicate with read/write head
0B
Watchdog reset
0C
Echo error in inductive transmission
0D
This function not available with the selected data carrier type
0E
The connected read/write head is not suitable for this control inter-
face unit
0F
Synchronisation error in control interface unit
10
Battery low (applies to battery-operated data carriers only) but
command was executed correctly.
11
Acknowledgment error in transmission to data carrier