IO-Link RFID Reader, HF 

3

 

Safety 

3.1

 

Safety-Relevant Symbols 

Danger!

 

 

This symbol warns of an immediate and present danger. 

Failure to observe this warning may result in personal injury or even death. 

Warning!

 

 

This symbol warns of a potential fault or hazard. 

Failure to observe this warning may result in personal injury or extensive damage to property. 

Caution

!

 

This symbol warns of a potential fault. 

Failure to observe this warning may result in the device and/or any systems and plants 
connected to it malfunctioning or failing completely. 

 

3.2

 

Intended Use 

The read/write head is designed to identify RFID read-only and read/write tags within a 
defined frequency range and should only be used for this purpose. 

Read through this manual carefully. Familiarize yourself with the device before installing, 
mounting, and operating it. 

Always operate the device as described in these instructions to ensure that the device and the 
connected systems function correctly. The protection of operating personnel and of the plant 
is only guaranteed if the device is operated in accordance with its intended use. 

 

3.3

 

General Safety Information 

The device must only be operated by specialist personnel who have received the relevant 
training in accordance with this instruction manual. 

If you open or modify the device yourself, not only are you endangering yourself and others 
but you will also void any warranty and absolve the manufacturer of any liability. Switch off the 
device if serious faults occur. Make sure that the device cannot be inadvertently switched on 
again. If the device needs to be repaired, return it to Fuchs. 

The device may only be connected by a qualified electrical specialist. The same applies for 
any maintenance work that needs to be carried out when the system is live. 

The operator is responsible for complying with all local safety regulations. 

Store the device in the original packaging when not in use. This offers the device optimal 
protection against impact and moisture. 

Содержание IQT1-18GM-IO-V1

Страница 1: ...MANUAL IO Link RFID Reader HF 13 56 MHz ISO 15693 IQT1 18GM IO V1 IQT1 F61 IO V1 IQT1 FP IO V1 FACTORY AUTOMATION...

Страница 2: ...st version of the General Terms of Delivery for Products and Services of the Electrical Industry set out by the German Electrical and Electronic Manufacturers Association ZVEI and the Extended Retenti...

Страница 3: ...O V1 7 3 4 2 IQT1 18GM IO V1 7 4 Product Description 8 4 1 Indicators and Operating Elements 8 4 2 Connection 9 4 3 Accessories 9 5 Installation 10 5 1 Storage and Transportation 10 5 2 Unpacking 10 5...

Страница 4: ...range of device functions avoid faulty operation and associated errors reduce costs associated with downtime and incidental repairs increase the effectiveness and economic efficiency of your plant St...

Страница 5: ...ence L exploitation est autoris e aux deux conditions suivantes 1 l appareil ne doit pas produire de brouillage et 2 l appareil doit accepter tout brouillage radio lectrique subi m me si le brouillage...

Страница 6: ...ensure that the device and the connected systems function correctly The protection of operating personnel and of the plant is only guaranteed if the device is operated in accordance with its intended...

Страница 7: ...tions 3 4 1 IQT1 IO V1 Warning Processes started in an uncontrolled manner jeopardize the plant Before commissioning ensure that there are no risks involved in using the device that may endanger the p...

Страница 8: ...ISO 15693 The devices are connected via M12 plugs Figure 4 1 IQT1 18GM IO V1 Figure 4 2 IQT1 F61 IO V1 Figure 4 3 IQT1 FP IO V1 4 1 Indicators and Operating Elements The IQH1 IO V1 read write heads h...

Страница 9: ...onnection to higher level devices via USB ICE1 8IOL G60L V1D Ethernet IO Link module with eight inputs outputs for connection to a higher level system via Ethernet IP Profinet or EtherCat You can use...

Страница 10: ...ease contact Pepperl Fuchs 5 3 Mounting and Connecting the Read Write Head Important note The read write head is intended for mounting indoors Do not mount the read write head on metal surfaces Mainta...

Страница 11: ...ith IQT1 IO V1 read write stations currently support the following read write tags 13 56 MHz ISO 15693 Tag Types The read write tags usually have a 64 byte unique read only code that has been defined...

Страница 12: ...ot transferred as cyclic process data You can select the read write command you want via the configuration tool from a list of possible read write commands 6 3 1 Command Overview Easy mode supports th...

Страница 13: ...ress user memory This parameter defines the start address from which the next command data is read from the user memory or written to the user memory The block length of the read write tag being used...

Страница 14: ...executed Bytes 1 2 and 3 are not used and are allocated zero because some controls such as the Rockwell Collins controls operate on four bytes Write data Bytes 4 to 31 contain the data in hexadecimal...

Страница 15: ...ehavior of the read write head The read bit in the output frame is true meaning that the read write head reads permanently If read write tag A now enters the detection range of the read write head the...

Страница 16: ...Install the software on your PC Now install the driver for the IO Link master and the IODD file for the read write head on your computer The driver and the IODD file can be found on the corresponding...

Страница 17: ...2017 07 17 IO Link RFID Reader HF Select the Online Parameterization menu option...

Страница 18: ...2017 07 18 IO Link RFID Reader HF The read write head automatically starts reading the UID of the read write tags The data can be found in the input frame of the process data...

Страница 19: ...2017 07 19 IO Link RFID Reader HF DOCT 5706A 06 2017...

Отзывы: