2
0
1
7
-0
7
13
IO-Link RFID Reader, HF
Choose read command
This parameter defines the read command that the write/read head will perform at the next
reading.
Value range:
UID, user memory
Default value: UID
Choose write command
This parameter defines the write command that the read/write head will perform at the next
writing.
Value range:
user memory
Default value: user memory
Number of bytes [user memory]
This parameter defines the number of bytes that the next command reads from the user
memory or writes to the user memory. The block length of the read/write tags being used and
the maximum available data range of 28 bytes per cycle should be observed. Read/write tag
type 37 cannot be used in easy mode as its block length of 32 bytes is larger than the
maximum available data range.
Value range:
4, 8, 12, 16, 20, 24, 28
Default value: 4
Format:
decimal
Starting address [user memory]
This parameter defines the start address from which the next command data is read from the
user memory or written to the user memory. The block length of the read/write tag being used
and the maximum available data range of 28 bytes per cycle should be observed. Read/write
tag type 37 cannot be used in easy mode as its block length of 32 bytes is larger than the
maximum available data range.
Value range:
depends on the size of the user memory and the block length
Default value: 0
Format:
hexadecimal
Autostart
This parameter defines whether or not the read command is carried out immediately when
you turn on the read/write head without taking into account the control bits of the process data
of the output frames.
Value range:
true, false
Default value: true
Process Data
The process data consists of an output frame and an input frame. The output frame contains
the data that is transferred cyclically from the IO-Link master to the reader. The input frame
contains the data that is transferred back from the reader to the IO-Link master.