![Pepperl+Fuchs IC-KP2-2HB21-2V1D Скачать руководство пользователя страница 66](http://html.mh-extra.com/html/pepperl-fuchs/ic-kp2-2hb21-2v1d/ic-kp2-2hb21-2v1d_manual_1527933066.webp)
201
2-
11
66
Commands
enhanced read special read only code (ES)
Command:
Response:
The R/W head attempts to read a
special read only code
until successful. Only
data that changes is transferred via the interface, i.e. the R/W head transfers data
whenever it reads a new data carrier or whenever it reads a data carrier where
there was previously no R/W head within the detection range.
The status '05h' (read command) is output whenever a data carrier leaves the
detection range.
Byte
Content
Bit no.
7
6
5
4
3
2
1
0
Byte 0
Control byte
0
0
0
0
0
D
S
U
M
U
S
Byte 1
Reserved
0
0
0
0
0
0
0
0
Byte 2
Command code
- 71
h
0
1
1
1
0
0
0
1
Byte 3
Reserved
0
0
0
0
0
0
0
0
Byte 4
Reserved
0
0
0
0
0
0
0
0
Byte 5
Reserved
0
0
0
0
0
0
0
0
Byte 6
Read only code length
<FixLen> (high byte)
Byte 7
Read only code length
<FixLen> (low byte)
Byte
Content
Bit no.
7
6
5
4
3
2
1
0
Byte 0
Control byte
0
0
0
0
0
D
S
U
M
U
S
Byte 1
Reserved
0
0
0
0
0
0
0
0
Byte 2
Command code
- 71
h
0
1
1
1
0
0
0
1
Byte 3
Reserved
0
0
0
0
0
0
0
0
Byte 4
Status
<Status>
Byte 5
Reply counter
<ReplyCounter>
Byte 6
Reserved
0
0
0
0
0
0
0
0
Byte 7
Reserved
0
0
0
0
0
0
0
0
Byte 8
ID code 00 ... FF
h
<IDCode>
ID code 00 ... FF
h
<IDCode>
Byte N
1)
ID code 00 ... FF
h
<IDCode>
Table 7.13
1) N = <FixLen> + 7
Note!
The <FixLen> of IDC-...-1K read/write tags is always 6 bytes.
Содержание IC-KP2-2HB21-2V1D
Страница 87: ...IC KP2 2HB21 2V1D ASCII table 2012 11 87 ...