fill read/write tag (S#)
Command:
Response:
The word number <WordNum> of fill signs <Fill Sign> is written to the read/write
tag from the specified start address <WordAddr>.
Extended commands for type IDC-... and IUC
…
tags
Type IDC-...-1K tags can be programmed to read 24-bit information (so-called
special read only code)
very quickly. This is useful for detecting containers in
automated warehouses.
Byte
Content
Bit no.
7
6
5
4
3
2
1
0
Byte 0
Control byte
0
0
0
0
0
D
S
U
M
U
S
Byte 1
Reserved
0
0
0
0
0
0
0
0
Byte 2
Command code
- AA
h
1
0
1
0
1
0
1
0
Byte 3
Reserved
0
0
0
0
0
0
0
0
Byte 4
Start address
<WordAddr> (high byte)
Byte 5
Start address
<WordAddr> (low byte)
Byte 6
Word count
<WordNum> (high byte)
Byte 7
Word count
<WordNum> (low byte)
Byte 8
Character
<Fill Sign>
Byte
Content
Bit no.
7
6
5
4
3
2
1
0
Byte 0
Control byte
0
0
0
0
0
D
S
U
M
U
S
Byte 1
Reserved
0
0
0
0
0
0
0
0
Byte 2
Command code
- AA
h
1
0
1
0
1
0
1
0
Byte 3
Reserved
0
0
0
0
0
0
0
0
Byte 4
Status
<Status>
Byte 5
Reply counter
<ReplyCounter>
Byte 6
Not used
-
-
-
-
-
-
-
-
Byte 7
Not used
-
-
-
-
-
-
-
-
Length of the
special read only code
:
■
Tag of the type IDC-...-1K:
48 bit
■
Tag of the type IUC:
96 ... 240 bit