![Pepperl+Fuchs IC-KP2-2HB21-2V1D Скачать руководство пользователя страница 39](http://html.mh-extra.com/html/pepperl-fuchs/ic-kp2-2hb21-2v1d/ic-kp2-2hb21-2v1d_manual_1527933039.webp)
Commands
201
2-
11
39
7.2.6
Standard read/write commands
single read read only code (SF)
Command:
Response:
The R/W head makes only one attempt to read a read only code.
The length of the read only code that is output depends on the tag type. See table
"Supported Tag Types" on page 31.
Byte
Content
Bit no.
7
6
5
4
3
2
1
0
Byte 0
Control byte
0
0
0
0
0
D
S
U
M
U
S
Byte 1
Reserved
0
0
0
0
0
0
0
0
Byte 2
Command code
- 01
h
0
0
0
0
0
0
0
1
Byte 3
Reserved
0
0
0
0
0
0
0
0
Byte 4
Not used
-
-
-
-
-
-
-
-
Byte 5
Not used
-
-
-
-
-
-
-
-
Byte 6
Not used
-
-
-
-
-
-
-
-
Byte 7
Not used
-
-
-
-
-
-
-
-
Byte
Content
Bit no.
7
6
5
4
3
2
1
0
Byte 0
Control byte
0
0
0
0
0
D
S
U
M
U
S
Byte 1
Reserved
0
0
0
0
0
0
0
0
Byte 2
Command code
- 01
h
0
0
0
0
0
0
0
1
Byte 3
Reserved
0
0
0
0
0
0
0
0
Byte 4
Status
<Status>
Byte 5
Reply counter
<ReplyCounter>
Byte 6
Reserved
0
0
0
0
0
0
0
0
Byte 7
Reserved
0
0
0
0
0
0
0
0
Byte 8
ID code 00h ... FF
h
<ID code>
...
ID code 00h ... FF
h
<ID code>
Byte N
1)
ID code 00h ... FF
h
<ID code>
Table 7.3
1) N = <FixLen> + 7
Содержание IC-KP2-2HB21-2V1D
Страница 87: ...IC KP2 2HB21 2V1D ASCII table 2012 11 87 ...