![Pepperl+Fuchs IC-KP2-2HB17-2V1D Скачать руководство пользователя страница 101](http://html1.mh-extra.com/html/pepperl-fuchs/ic-kp2-2hb17-2v1d/ic-kp2-2hb17-2v1d_manual_1527662101.webp)
Appendix A
2014-
02
101
Reading tags of the read/write heads on channel 1 and channel 2.
Send the command single read to channel 1 as an implicit command:
Confirmation
Response
Note!
Alternatively select the tag type by configuring the relevant setting in the boot-up object.
Byte no.
Use
Type
Description
Byte 0
Command code
01h
Command
SF
(single read fixcode)
Byte 1
Channel/Toggle bit
02h
Channel = 1
Toggle bit = 0
Byte 2
00h
Byte 3
00h
Byte 4
00h
Byte 5
00h
Byte 6
00h
Byte 7
00h
Byte 8
00h
Byte 9
00h
Byte 10
00h
byte 11
00h
Byte no.
Use
Type
Description
Byte 0
Command code
01h
Command
SF
(single read fixcode)
Byte 1
Channel/Toggle bit
02h
Channel = 1
Toggle bit = 0
Byte 2
Status
FFh
Processing command.
Byte 3
Reply counter
05h
For every ident telegram, the value
on the reply counter increases by
1.
Byte 4
00h
Byte 5
00h
Byte 6
00h
Byte 7
00h
Byte 8
00h
Byte 9
00h
Byte 10
00h
byte 11
00h
Byte no.
Use
Type
Description
Byte 0
Command code
01h
Command
SF
(single read fixcode)
Byte 1
Channel/Toggle bit
02h
Channel = 1
Toggle bit = 0
Byte 2
Status
00h
Command executed.