Product Description
2014-
02
15
4.7
Displays and Controls
LEDs
Operating controls
Description Function
Status description
1
2
Status display for
the read/write
heads
LED illuminates
green
when there is an active command on
the read/write head.
LED illuminates
yellow
for approx. 1 second when a
command is executed successfully.
CH1
CH2
Displays the
read/write heads
connected
(channel)
LED illuminates
green
when a read/write head is connected
to channel 1 or channel 2.
LED illuminates
red
if a configuration error occurs.
PWR/ERR Status display for
the IDENTControl
Compact
LED illuminates
green
when the IDENTControl Compact is
connected to a power supply and the interface is ready for
operation.
LED illuminates
red
if there is a hardware error or a
PROFINET name has been assigned and no PROFINET
connection has been established.
LED illuminates
yellow
while the IDENTControl Compact
starts up. The start-up process lasts approximately 20
seconds
LED flashes
green
if a signal is sent to the IDENTControl
Compact via the "Flashing" PROFINET function or if there is
an internal data overflow.
Link/Traffic Connection/networ
k activity for the
relevant channel
(1/2)
LED is off until initial communication is made via Ethernet.
LED illuminates
green
when a connection to the network is
established.
LED flashes
yellow
at the same speed as the data being
sent.
ADDR
STATE
Status display for
address setting
LED flashes
green
when the IDENTControl Compact is
ready for the address to be entered using the rotary switch.
LED illuminates
green
when one digit of the address is
entered successfully using the rotary switch.
Description
Function
Configuration option
Rotary switch
Device address setting
0 ... F
CH2
CH2
CH1
CH1
1
2
PWR/ERR
0
8
C
4
F
7
B
3
E
6
A
2
D
5
9
1
Link/
Traffic
Link/
Traffic
Address
configuration
Address
state