48
6100 Series Manual
7 Maintenance and Repair
1. The 6100 purge and pressurization system does not require special maintenance except replacement
of pneumatic filters, when used, and normal periodic functional checks, including pressure and flow
readings within specifications contained in this manual. When checking whether the pressure and flow
measurements of the EPV-6100 vent are within specifications, use calibrated equipment to determine
measurements, or contact a Fuchs representative or the factory to send back the EPV-6100 vent
for pressure and flow verification.
2. The purge and pressurization system, when operated in conjunction with a hazardous area, must not be
modified. If there is a defect, the product may need to be replaced. Repairs must be performed only by a
Fuchs specialist who is specifically trained and authorized to repair the defect.
3. Any replaceable fuses must be replaced with specific fuse ratings and type, as written in this manual
under Specifications.
4. When servicing, installing, and commissioning, the area must be free of all combustible material and/or
hazardous explosive gas. Only the terminal compartment of the control unit is accessible to the user. Not
under any circumstances, shall the control unit, user-interface, or vent, be taken apart. The Ex d housing
cover shall only be removed when power is removed from the device or the area is known to be safe.
5. Any cable glands that require replacement shall be replaced with the same model or another approved
cable gland that meets the area classification.
6. When replacing the EPCU, the area must be free of hazardous gas and/or dust and power removed from
the EPCU, enclosure contacts, and auxiliary contacts. Two screws on the bottom of the Ex d enclosure
need to be loosened but not removed. Twist the EPCU clockwise and lift it out of the Ex d enclosure.
Reverse to install new EPCU.
Contact customer service for an RMA (return merchandise authorization).
Maintenance and Repair
Содержание Bebco EPS 6100-MP-EX Series
Страница 1: ...MANUAL 6100 Series Bebco EPS 6100 Series Ex pxb Purge and Pressurization System...
Страница 57: ...57 6100 Series Manual SETUP PASSWORD BYPASS PASSWORD DATE NAME Appendix...
Страница 58: ...58 6100 Series Manual 10 2 Type Codes Appendix...
Страница 59: ...59 6100 Series Manual Notes...