CP302
CP-RIO3-01 Rear I/O Module
ID 21112, Rev. 05
Page D - 11
®
PEP Modular Computers GmbH
D.4.7 Fan Control Interface (optional)
A fan for CPU cooling can be connected via the power connector CON9.
D4.7.1
Fan Control Connector CON9 Pinout
D.4.8 EIDE Interface
D.4.8.1 EIDE Connector EIDE2 (CON7) Pinout
The following table sets out the pin numbers of connector CON7 and sets out its
corresponding signal names and functions.
Table D-6: Fan Control Connector CON9 Pinout
Pin
Function
1
Ground
2
5V Fan Supply Voltage at a maximum current of 300 mA
3
Fansense
Table D-7: Pinout of AT Standard Connector EIDE2
Pin
Signal
Function
In/Out
1
IDERESET
Reset HD
Out
2
GND
Ground signal
--
3
HD7
HD data 7
In/Out
4
HD8
HD data 8
In/Out
5
HD6
HD data 6
In/Out
6
HD9
HD data 9
In/Out
7
HD5
HD data 5
In/Out
8
HD10
HD data 10
In/Out
9
HD4
HD data 4
In/Out
10
HD11
HD data 11
In/Out
11
HD3
HD data 3
In/Out
12
HD12
HD data 12
In/Out
13
HD2
HD data 2
In/Out
Table continued on following page
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com