76180 EM -34/73-
12-2. Adjustment
①
Connect the camera to the PC, and adjust the shutter speed by the programmed software.
[The flow of adjustment is as follows.]
↓
Product select menu (Select
*istD)
↓
76180 test program
(
Select
1
even when you replace 0-T100.
)
↓
Main menu (Select 7 )
↓
Shutter speed adjustment
②
Adjust the camera according to the instructed on the screen.
[NOTE] Read the shutter speed displayed on the window B as shown in the figure above.
③
Return to the MAIN MENU to finish the adjustment when the adjustment is completed.
④
Execute Eeprom checking (END) (select 5)
If standard data is NG, re-write by pressing 3. Other adjustments carry out on section 23.
⑤
Return to the MAIN MENU to finish the adjustment.
12-3. Remove temporally installed for camera.
①
Unsolder the I/F buffer cable and black lead wire No.6 (T800).
②
Remove the top cover and bottom cover.
③
Peel off PT (20x20) on the left side of the pentaprism.
13. [CONF] CCD Base Plate Support Pillar
[Required equipment] Block gauge for 35mm, Dial gauge comparator, etc. (same as MZ series)
①
Measure height of the CCD base support pillar (3 places) from the mount surface as shown
in the figure.
Tolerance: 47.85
±
0.02 mm
14. 0-T600 (CCD Block)
[Preparation] Attach the body mount cap to the camera to prevent damage of Tv dial.
[CAUTION] Confirm there is neither dust nor scratches in the surface of CCD of T600.
①
Put 0-T750 (USB P.C. board assy.) on the flexible board of T960.
②
Temporarily tighten CNL-D1.7x2.5 (3pcs.) a little bit loosely so that 0-T750 moves.
・・・
Two washers should be placed at the USB part underneath 0-T750.
③
Connect the flexible board of T960 to the connector terminal of 0-T750.
④
Connect 0-T600 to the connector terminal of T960.
when using the block gauge for 35mm:
+
2.39
±
0.02 mm
+0.39
+2.00
+2.39