76180 EM -24/73-
20-2. Adjustment
①
Connect the DC cord to the camera. Confirm that the camera must be turned ON without a
short circuit or leakage 5 seconds after the DC cord is connected to the camera. (Main
SW/ON: Light metering OFF: Ave. 240mA, Light metering ON: Ave. 420mA)
②
Solder a resistance (200~250
Ω
) to T301 as shown in the figure.
③
Confirm the all displays must be turned on. (Some beginnings productions are required
depressing the release button halfway down by using cable switch.)
④
Confirm the LCD in the viewfinder is in place as shown in the figure above.
⑤
Loosen the retainer screws of LCD, and then adjust the position of LCD.
⑥
After adjustment is done, apply the screw-lock agent to 4 screws.
⑦
Remove all lead wires and a resistance.
21. 0-T100 (2)
①
TY-CNL-D1.4x2.5
②
0-T100
・・・
DT
③
Connect the flexible board of 0-M100 to 0-T100.
④
T69 (15x8)
⑤
0-I331
⑥
TY-CNL-G1.7x2.5
⑦
TY-CNL-D1.4x2.5 (A101, Upper left)
⑧
Solder 4 lands.
・・・
S300, 0-T100
⑨
Solder 2 lead wires
・・・
Brown, Black
⑩
BT (25x15)
・・・
Arrange the lead wires of S300
200-250Ω
②
⑤
⑥
①
②
③
④
⑦
⑧
⑨
⑩