8
PENTALIFT EQUIPMENT CORPORATION
M086R06
December 8, 2017 10:37 AM
LDL Dock Lift Owners Manual
ELECTRICAL REFERENCE - 7.5 HP
Length of
branch circuit
which will have
a 2% voltage
drop at full load
current (copper
wire) ft/m.
The values
given are
intended to be
a rough wiring
guide only.
Be sure to
check all local
electrical codes
before wiring.
AWG
115/1/60
230/1/60
230/3/60
380/3/50
460/3/60
575/3/60
14
136 ft
223 ft
374 ft
12
89 ft
217 ft
354 ft
595 ft
10
141 ft
344 ft
563 ft
945 ft
8
104.6 ft
224 ft
578 ft
896 ft
1504 ft
6
166 ft
356 ft
871 ft
1424 ft
2391 ft
Approximate Motor
Current (full load)
33 A
18.8 A
12.7 A
9.4 A
7 A
ELECTRICAL REFERENCE - 10 HP
Length of
branch circuit
which will have
a 2% voltage
drop at full load
current (copper
wire) ft/m.
The values
given are
intended to be
a rough wiring
guide only.
Be sure to
check all local
electrical codes
before wiring.
AWG
115/1/60
230/1/60
230/3/60
380/3/50
460/3/60
575/3/60
14
145 ft
273 ft
12
178 ft
231 ft
434 ft
10
92 ft
282 ft
368 ft
689 ft
8
146 ft
448 ft
585 ft
1096 ft
6
232 ft
714 ft
930 ft
1743 ft
Approximate Motor
Current (full load)
28.8 A
15.5 A
14.4 A
9.6 A