7
PENTALIFT EQUIPMENT CORPORATION
M086R06
December 8, 2017 10:37 AM
LDL Dock Lift Owners Manual
ELECTRICAL REFERENCE - 3 HP
Length of
branch circuit
which will have
a 2% voltage
drop at full load
current (copper
wire) ft/m.
The values
given are
intended to be
a rough wiring
guide only.
Be sure to
check all local
electrical codes
before wiring.
AWG
115/1/60
230/1/60
230/3/60
380/3/50
460/3/60
575/3/60
14
59 ft
87 ft
368 ft
106 ft
545 ft
12
94 ft
139 ft
585 ft
169 ft
867 ft
10
39 ft
150 ft
221 ft
930 ft
269 ft
1379 ft
8
62 ft
238 ft
351 ft
1480 ft
428 ft
2193 ft
6
98 ft
379 ft
558 ft
2353 ft
680 ft
3486 ft
Approximate Motor
Current (full load)
28 A
14.5 A
12 A
4.7 A
6 A
4.8 A
ELECTRICAL REFERENCE - 5 HP
Length of
branch circuit
which will have
a 2% voltage
drop at full load
current (copper
wire) ft/m.
The values
given are
intended to be
a rough wiring
guide only.
Be sure to
check all local
electrical codes
before wiring.
AWG
115/1/60
230/1/60
230/3/60
380/3/50
460/3/60
575/3/60
14
87 ft
228 ft
106 ft
545 ft
12
139 ft
362 ft
169 ft
867 ft
10
103 ft
221 ft
575 ft
269 ft
1379 ft
8
164 ft
351 ft
915 ft
428 ft
2193 ft
6
261 ft
558 ft
1455 ft
680 ft
3486 ft
Approximate Motor
Current (full load)
21 A
12 A
7.6 A
6 A
4.8 A