background image

10

11

SILENTFLO

 Pool Pump

 Owner’s Manual 

SILENTFLO™ Pool Pump

 Owner’s Manual

PLUMBING

 

800mm

Certified Anti-entrapment 

Cover or Suction Fitting, 

screw fastened to Main 

Drain Sump

Suction Outlet 

(Main Drain)

Valves OK between 

pump and Tee

Pump

Certified Anti-entrapment 

Cover or Suction Fitting, 

screw fastened to Main 

Drain Sump

Suction Outlet 

(Main Drain)

No valves between Tee 

and Main Drains

PLUMBING

Pump suctions are hazardous and can trap and drown or disembowel bathers. Do not 
use or operate pump, pool or spa if a suction outlet cover is missing, broken, or loose. 
Follow the guidelines below for a pump installation which minimises risk to users or 
pools and spas.

Entrapment Protection

The pump suction system must provide protection against hazard of suction 
entrapment or hair entrapment/entanglement.

Testing and Certification

Suction outlet covers must have been tested by a nationally recognised testing 
laboratory and found to comply with the latest AS1926.3 standard or ASME/ANSI 
specification for Suction Fittings For Use in Swimming Pools, Spas, Hot Tubs, and 
Whirlpool Bathtub Applications.

Outlets Per Pump

Provide at least two hydraulically balanced main drains, with covers, for each 
swimming pool pump suction line. The centres of the main drains (suction fittings) 
must be at least 800mm apart.
The system must be built so that it cannot operate with the pump drawing water from 
only one main drain (that is, there must be at least two main drains connected to the 
pump whenever it is running). However, if two main drains run into a single suction 
line, the single suction line may be equipped with a valve which will shut off both main 
drains from the pump.
More than one pump can be connected to a single suction line as long as the 
requirements above are met.

Water Velocity

The maximum water velocity through any suction outlet must comply with the 
latest AS1926.3 Standard or ASME/ANSI Specification for Suction Fittings For Use in 
Swimming Pools, Spas, Hot Tubs, and Whirlpool Bathtub Applications.

Hazardous suction. 
Can trap hair or body 
parts, causing severe 
injury or death.

DO NOT BLOCK 
SUCTION.

Содержание STA-RITE SILENTFLO SF1100100

Страница 1: ...tected by a residual current device RCD with a maximum rated residual current of 30mA Should the installer or owner be unfamiliarwiththecorrectinstallationoroperationofthistypeofequipmentyoushould con...

Страница 2: ...P1 P2 SF550100 600 450 230 240V 0 75 56 2 6 14 30 SF750100 740 550 230 240V 1 0 56 3 3 14 30 SF1100100 1050 790 230 240V 1 5 59 5 0 22 25 SF1500100 1590 1190 230 240V 2 0 61 6 7 28 35 Motor Type TEFC...

Страница 3: ...afety Children should be supervised to ensure that they do not play with the appliance If the supply cord is damaged it must be replaced by the manufacturer its service agent or similarly qualified pe...

Страница 4: ...h protects the motor from heat damage during operation Only qualified licensed personnel should install pump The electrical installation shall be in accordance with the national wiring rules AS NZS 30...

Страница 5: ...on to maintain air tempertaure at less than the maximum ambient temperture rating If this pump is installed in an enclosure pump house the enclosure must have adequate ventilation 200sq cm min inlet o...

Страница 6: ...atest AS1926 3 standard or ASME ANSI specification for Suction Fittings For Use in Swimming Pools Spas Hot Tubs and Whirlpool Bathtub Applications Outlets Per Pump Provide at least two hydraulically b...

Страница 7: ...eeds replacement insist on genuine ONGA service parts Clean and inspect o ring reinstall on trap Replace trap lid turn clockwise to tighten by hand only no wrenches Pump should prime now Priming time...

Страница 8: ...personel For best results use only genuine ONGA service parts Be sure to prime pump before starting Before removing clamp or trap cover 1 SWITCH OFF POWER to pump before proceeding 2 CLOSE SHUT OFF VA...

Страница 9: ...k Motor termal overload tripped Check for required ventilation and cooling If temperature is above the pump s maximum ambient turn off pump until it cools down No power at outlet Use another electrici...

Страница 10: ...er and O Ring Kit 9 O RING DIFFUSER See Diffuser and O Ring Kit 10 SCREW 8 32 x 22mm SS PHILLIPS HEAD See Diffuser and O Ring Kit DIFFUSER O RING KIT INCLUDES ITEM 8 9 10 x7 801421 801422 801423 80142...

Страница 11: ...Australia Holdings Pty Ltd under Australian copyright law Content may not be reproduced or transmitted without our prior written permission Disclaimer Pentair reserves the right to change product spe...