INSTALLATION

INSTALLATION

SilentFlo is electrically connected. Ensure that it is isolated from 
electrical supply during installation and any subsequent service 
work.

The pump should be installed and serviced by a suitably qualified 
person in order to avoid hazard.

These instructions are a guide only. Should you the installer or owner 
of the product be unfamiliar with the correct installation or operation 
of this product you should contact a suitably qualifed person for 
advice.

Freezing conditions will damage the unit, as water expands as it 
freezes. Ensure that Silentflo is located so that it is not prone to 
freezing, or ensure that the product is disconnected and dried of 
water during cold conditions.

This appliance is not intended for use by persons (including children) 
with reduced physical, sensory or mental capabilities, or lack of 
experience and knowledge, unless they have been given supervision 
or instruction concerning use of the appliance by a person 
responsible for their safety.

Children should be supervised to ensure that they do not play with 
the appliance.

If the supply cord is damaged, it must be replaced by the 
manufacturer, its service agent or similarly qualified persons in order 
to avoid a hazard.

 

 

The pump operator or owner must be provided with this owner’s 
manual. This must be read before operation, and followed during 
operation.

NEVER run pump dry. Running pump dry may damage seals, causing 
leakage and flooding. Fill pump with water before starting motor.

If pump has been pressure tested, ensure pressure has been 
released before removing trap lid. Do not block pump suction. To do 
so with body may cause severe or fatal injury.

Small children using pool must ALWAYS have close adult supervision. 

Pump suction is hazardous and can trap and drown or disembowel 
bathers. Do not use or operate pump, pool/spas if a suction outlet 
cover is missing, broken, or loose. Follow the guidelines below for a 
pump installation which minimises risk to users of pool and spas.

Fire and burn hazard. Modern motors run at high temperatures. To 
reduce the risk of fire, do not allow leaves, debris, or foreign matter 
to collect around the pump motor. To avoid burns when handling the 
motor, let it cool for at least 20 minutes before trying to work on it.

Содержание STA-RITE SILENTFLO SF1100100

Страница 1: ...tected by a residual current device RCD with a maximum rated residual current of 30mA Should the installer or owner be unfamiliarwiththecorrectinstallationoroperationofthistypeofequipmentyoushould con...

Страница 2: ...P1 P2 SF550100 600 450 230 240V 0 75 56 2 6 14 30 SF750100 740 550 230 240V 1 0 56 3 3 14 30 SF1100100 1050 790 230 240V 1 5 59 5 0 22 25 SF1500100 1590 1190 230 240V 2 0 61 6 7 28 35 Motor Type TEFC...

Страница 3: ...afety Children should be supervised to ensure that they do not play with the appliance If the supply cord is damaged it must be replaced by the manufacturer its service agent or similarly qualified pe...

Страница 4: ...h protects the motor from heat damage during operation Only qualified licensed personnel should install pump The electrical installation shall be in accordance with the national wiring rules AS NZS 30...

Страница 5: ...on to maintain air tempertaure at less than the maximum ambient temperture rating If this pump is installed in an enclosure pump house the enclosure must have adequate ventilation 200sq cm min inlet o...

Страница 6: ...atest AS1926 3 standard or ASME ANSI specification for Suction Fittings For Use in Swimming Pools Spas Hot Tubs and Whirlpool Bathtub Applications Outlets Per Pump Provide at least two hydraulically b...

Страница 7: ...eeds replacement insist on genuine ONGA service parts Clean and inspect o ring reinstall on trap Replace trap lid turn clockwise to tighten by hand only no wrenches Pump should prime now Priming time...

Страница 8: ...personel For best results use only genuine ONGA service parts Be sure to prime pump before starting Before removing clamp or trap cover 1 SWITCH OFF POWER to pump before proceeding 2 CLOSE SHUT OFF VA...

Страница 9: ...k Motor termal overload tripped Check for required ventilation and cooling If temperature is above the pump s maximum ambient turn off pump until it cools down No power at outlet Use another electrici...

Страница 10: ...er and O Ring Kit 9 O RING DIFFUSER See Diffuser and O Ring Kit 10 SCREW 8 32 x 22mm SS PHILLIPS HEAD See Diffuser and O Ring Kit DIFFUSER O RING KIT INCLUDES ITEM 8 9 10 x7 801421 801422 801423 80142...

Страница 11: ...Australia Holdings Pty Ltd under Australian copyright law Content may not be reproduced or transmitted without our prior written permission Disclaimer Pentair reserves the right to change product spe...