Installer Manual Siata V132-SFE-EV-VIRIDION - Operation
Ref. MKT-IM-009 / C - 08.06.2018
73 / 110
Method 2
The controller incorporates a counter that is decreased by one unit at each regeneration. As soon as
the counter reaches zero, the salt alarm icon is activated on the display (in three languages: French,
German and English) and any regeneration is postponed until the alarm has been manually
deactivated. Once the alarm is removed, the controller will start any postponed regeneration. Press
any key to exit alarm. See “Number of regenerations before salt alarm”, page 58. If during the service
the
button is pressed for 5 seconds, the salt alarm count down will be restored, display will show
SAL
to confirm that.
8.10. Operation during a power failure
The following conditions may arise when there is a power failure.
During stand-by, during parameter restore or during statistical analysis
In all these cases, the module returns to stand-by and displays the clock with battery icon on to
indicate there is no mains power. If there is a power outage during parameter restore, the system
exits restore status without saving any changes made. When power is restored, it will be necessary to
go back to parameter restore and carry out the changes again.
During regeneration cycle movement or end of cycle search
In this case, the controller continues to display the current stage, the battery icon is turned on to
indicate that mains power is off, the revolving bar is locked to indicate that the motor is off. When
mains power is restored, the motor starts again and will complete the movement.
During regeneration cycle pause
In this case, the controller continues to display the current stage, the battery icon is turned on to
indicate that mains power is off, the pause timer is stopped. When mains power is restored, the pause
timer will resume and the system will move onto the next stage.
During an alarm
In this case, the module continues to display the alarm and the battery icon is turned on to indicate
that mains power is off. The controller will remain in alarm status when mains power is restored.
8.11. Other Key Functions
•
Press and hold the
and
buttons for 5 seconds to display the programmed maintenance
phone number;
•
in standby press and hold
button for 5 seconds to reset the salt alarm countdown;
•
during the regeneration press and hold
button for 5 seconds to reset the salt alarm
countdown.
Содержание SIATA V132-SFE-EV-VIRIDION
Страница 1: ...SIATA V132 SFE EV VIRIDION INSTALLER MANUAL WATER PURIFICATION...
Страница 17: ...Installer Manual Siata V132 SFE EV VIRIDION Description Ref MKT IM 009 C 08 06 2018 17 110 3 3 Outline drawing...
Страница 77: ...Installer Manual Siata V132 SFE EV VIRIDION Maintenance Ref MKT IM 009 C 08 06 2018 77 110...
Страница 79: ...Installer Manual Siata V132 SFE EV VIRIDION Maintenance Ref MKT IM 009 C 08 06 2018 79 110...
Страница 81: ...Installer Manual Siata V132 SFE EV VIRIDION Maintenance Ref MKT IM 009 C 08 06 2018 81 110...
Страница 83: ...Installer Manual Siata V132 SFE EV VIRIDION Maintenance Ref MKT IM 009 C 08 06 2018 83 110...
Страница 85: ...Installer Manual Siata V132 SFE EV VIRIDION Maintenance Ref MKT IM 009 C 08 06 2018 85 110...
Страница 87: ...Installer Manual Siata V132 SFE EV VIRIDION Maintenance Ref MKT IM 009 C 08 06 2018 87 110...
Страница 89: ...Installer Manual Siata V132 SFE EV VIRIDION Maintenance Ref MKT IM 009 C 08 06 2018 89 110...
Страница 91: ...Installer Manual Siata V132 SFE EV VIRIDION Maintenance Ref MKT IM 009 C 08 06 2018 91 110...
Страница 110: ...www pentairaquaeurope com...