Pentair PF6-P Скачать руководство пользователя страница 7

Do not perform the Fluoride Filter Wash until the Fluoride Filter Soak process is complete.

Water will flow out of the downflow inlet side of the Bypass Valve during this process. Be sure you perform this series of 

steps in a location suitable for water flow.

FLUORIDE FILTER WASH

1. Reattach the garden hose to the Hose Bib Assembly.

2. Slowly turn on the water 1/4 turn for this entire process.

3. Run water through the upflow inlet side of the Bypass Valve for 15-30 minutes or until the water discharging from the  

  downflow inlet side of the Bypass Valve runs clear.

4. Turn off the water.

5. Remove the Hose Bib Assembly from the upflow inlet side and attach it to the downflow inlet side of the Bypass Valve.

6. Run the water through the downflow inlet side for 1 minute or until water runs clear.

7. Turn off the water.

8. Remove the Hose Bib Assembly from the Bypass Valve and disconnect the garden hose.

 

Top View

Whole House Fluoride Filter

Garden 

Hose

Hose Bib

Assembly

Water

Bypass Valve

OUTLET

INLET

IMPORTANT

Note

Please save the Hose Bib Assembly as this will be used in the future for the carbon exchange.

Note

FLUORIDE WATER FILTER SYSTEM • 7

Содержание PF6-P

Страница 1: ...pentair com homewater FLUORIDEWATERFILTERSYSTEM PF6 P...

Страница 2: ...e bridging the equipment and re establishing the contiguous conductive nature of the plumbing system must be installed prior to your systems use WARNING When adding a filtration softening system to ho...

Страница 3: ...CHNOLOGYwill be effective on water supplies with a maximum hardness of 75 Grainsper Gallon GPG or 1 282 ppm For best results all iron manganese sulfur and Tannin should be removed prior to this system...

Страница 4: ...op View 19 Front View Shut Off Valves Sediment Filter Water to Home Fluoride Filter Bypass Outgoing Water to House Sediment filter position is at the discretion of your professional installer As a gen...

Страница 5: ...the arrows on your bypass valve s do not match the diagram remove the red arrows by pulling them straight up turn them 180 to match the drawing and push them back down onto the stem Note Top View T Q...

Страница 6: ...e to the Hose Bib Assembly 2 Connect the Hose Bib Assembly to the upflow inlet side of the Bypass Valve and hand tighten 3 Fill the Pentair Whole House Fluoride Filter Tank full until water comes out...

Страница 7: ...tes or until the water discharging from the downflow inlet side of the Bypass Valve runs clear 4 Turn off the water 5 Remove the Hose Bib Assembly from the upflow inlet side and attach it to the downf...

Страница 8: ...TER SOFTENER ALTERNATIVE WITH NATURSOFT SALT FREE TECHNOLOGY 7 Part 1 1 Unscrew the cover from the blue filter housing 2 Remove the plastic covering from the sediment filter 3 Place the sediment filte...

Страница 9: ...n tips for leveling the tank If the tank is not level lift the tank straight up 6 inches and tap it on the ground until the tank stands vertical The bottom of the tank is round and the boot allows the...

Страница 10: ...in the desired location on the tank 4 Wax stainless steel tank jacket s with wax provided or any other non abrasive auto wax a minimum of 1 2 times per year or as needed based on the installed enviro...

Страница 11: ...ess the upper o rings down into the groove with two fingers This step is important to ensure the proper filter seal Make sure the upper o rings is seated level in the groove If the o ring appears dama...

Страница 12: ...ter be replaced every 6 9 months depending on the amount of sediment present in the water supply If the system has been working properly and the pressure is slowing it may be time to change the sedime...

Страница 13: ...antyto complete the warranty registration form online For details on your Pentair product warranty please visit Send to Pentair 2361 Mason Avenue Suite 100 Daytona Beach FL 32117 Phone 1 800 842 1635...

Страница 14: ...14 FLUORIDEWATERFILTERSYSTEM...

Страница 15: ...FLUORIDEWATERFILTERSYSTEM 15...

Страница 16: ...ty of Pentair Third party registered and unregistered trademarks and logos are the property of their respective owners 4006101RevA MY21 2361 Mason Ave Suite 100 Daytona Beach FL 32117 United States P...

Отзывы: