Sediment Filter

It is recommended that the sediment filter be replaced every 6-9 months depending on the amount of sediment present in the

water supply. If the system has been working properly and the pressure is slowing, it may be time to change the sediment filter.

Check the sediment filter and replace if necessary.

Replacing the Sediment Filter

1. Turn off the main water supply to the sediment filter system and bypass all tanks.
2. Run a faucet (cold water) inside the house to relieve the pressure. Leave the faucet open.
3. Unscrew the blue filter housing clockwise using the supplied filter wrench.
4. Remove the existing sediment filter and discard.
5. Remove the o-rings and wipe the upper groove clean. Lubricate two new o-rings with a coating of clean silicone grease.

  Replace both o-rings. Be sure to press the upper o-rings down into the groove with two fingers.

  This step is important to ensure the proper filter seal. Make sure the upper o-rings is seated level in the groove. If the

  o-ring appears damaged, stretched, or crimped it should be replaced.

6. Place a new sediment filter onto the stand pipe in the blue filter housing.
7. Screw the blue filter housing onto the filter cover hand tight. Lightly snug the housing with the spanner wrench making sure

  not to over-tighten.
8. Turn on the main water supply slowly to allow the sediment filter system to fill with water and expel air from lines. Put tanks

  back in service (out of bypass).
9. Check for leaks.

Sediment Filter Cover

Sediment Filter

O-Ring  x2

Stand Pipe

Blue Filter Housing

WATER SOFTENER ALTERNATIVE WITH NATURSOFT® SALT-FREE TECHNOLOGY

  • 11

Note

MAINTENANCE

Media Replacement

Your Pentair PF6-P Whole House Fluoride Filter requires care and cleaning after a period of 3 years. Replacement media and 

instructions can be ordered on-line at Pentair.com/homewater or by calling 877-842-1635.

FLUORIDE WATER FILTER SYSTEM

 • 11

Содержание PF6-P

Страница 1: ...pentair com homewater FLUORIDEWATERFILTERSYSTEM PF6 P...

Страница 2: ...e bridging the equipment and re establishing the contiguous conductive nature of the plumbing system must be installed prior to your systems use WARNING When adding a filtration softening system to ho...

Страница 3: ...CHNOLOGYwill be effective on water supplies with a maximum hardness of 75 Grainsper Gallon GPG or 1 282 ppm For best results all iron manganese sulfur and Tannin should be removed prior to this system...

Страница 4: ...op View 19 Front View Shut Off Valves Sediment Filter Water to Home Fluoride Filter Bypass Outgoing Water to House Sediment filter position is at the discretion of your professional installer As a gen...

Страница 5: ...the arrows on your bypass valve s do not match the diagram remove the red arrows by pulling them straight up turn them 180 to match the drawing and push them back down onto the stem Note Top View T Q...

Страница 6: ...e to the Hose Bib Assembly 2 Connect the Hose Bib Assembly to the upflow inlet side of the Bypass Valve and hand tighten 3 Fill the Pentair Whole House Fluoride Filter Tank full until water comes out...

Страница 7: ...tes or until the water discharging from the downflow inlet side of the Bypass Valve runs clear 4 Turn off the water 5 Remove the Hose Bib Assembly from the upflow inlet side and attach it to the downf...

Страница 8: ...TER SOFTENER ALTERNATIVE WITH NATURSOFT SALT FREE TECHNOLOGY 7 Part 1 1 Unscrew the cover from the blue filter housing 2 Remove the plastic covering from the sediment filter 3 Place the sediment filte...

Страница 9: ...n tips for leveling the tank If the tank is not level lift the tank straight up 6 inches and tap it on the ground until the tank stands vertical The bottom of the tank is round and the boot allows the...

Страница 10: ...in the desired location on the tank 4 Wax stainless steel tank jacket s with wax provided or any other non abrasive auto wax a minimum of 1 2 times per year or as needed based on the installed enviro...

Страница 11: ...ess the upper o rings down into the groove with two fingers This step is important to ensure the proper filter seal Make sure the upper o rings is seated level in the groove If the o ring appears dama...

Страница 12: ...ter be replaced every 6 9 months depending on the amount of sediment present in the water supply If the system has been working properly and the pressure is slowing it may be time to change the sedime...

Страница 13: ...antyto complete the warranty registration form online For details on your Pentair product warranty please visit Send to Pentair 2361 Mason Avenue Suite 100 Daytona Beach FL 32117 Phone 1 800 842 1635...

Страница 14: ...14 FLUORIDEWATERFILTERSYSTEM...

Страница 15: ...FLUORIDEWATERFILTERSYSTEM 15...

Страница 16: ...ty of Pentair Third party registered and unregistered trademarks and logos are the property of their respective owners 4006101RevA MY21 2361 Mason Ave Suite 100 Daytona Beach FL 32117 United States P...

Отзывы: