P/N 475106 Rev. D 1/2016 MASTERTEMP
™
Pool and Spa Heater Installation and User’s Guide
|
13
OUTDOOR INSTALLATION
For heaters located outdoors, using the built-in stackless venting system.
DANGER
CARBON MONOXIDE GAS IS DEADLY – Exhaust from this pool heater contains carbon monoxide, a dangerous, poisonous gas you
cannot see or smell. Symptoms of carbon monoxide exposure or poisoning include dizziness, headache, nausea, weakness, sleepiness,
muscular twitching, vomiting and inability to think clearly. IF YOU EXPERIENCE ANY OF THE ABOVE SYMPTOMS, IMMEDIATELY
TURN OFF THE POOL HEATER, LEAVE THE VICINITY OF THE POOL OR SPA AND GET INTO FRESH AIR IMMEDIATELY.
THE POOL HEATER MUST BE THOROUGHLY TESTED BY A GAS PROFESSIONAL BEFORE RESUMING OPERATION.
EXCESSIVE CARBON MONOXIDE EXPOSURE CAN CAUSE BRAIN DAMAGE OR DEATH.
WARNING
Risk of explosion if a unit burning G31 is installed in a pit or other low spot. G31 is heavier than air. Do not install the heater
using propane in pits or other locations where gas might collect. Consult the European Standard Codes of Practice building code
officials to determine installation requirements and specific installation restrictions of the heater relative to propane storage tanks and
filling equipment. Installation must meet the requirements for the Standard for the Storage and Handling of Liquid Petroleum Gases.
Consult local codes and fire protection authorities about specific installation restrictions.
Locate the heater in an open, unroofed area and on a level surface that is protected from drainage or run-off. Install the
heater in an area where leaves or other debris will not collect
on or around the heater.
It is recommended that a non-combustible base be a platform
under the heater constructed of hollow masonry blocks, not
less than 100 mm (4 in) thick (laid with ends unsealed and
joints matched for air circulation). Cover blocks with 0.75
mm (0.03 in) minimum galvanized sheet metal, see
Figure 15
.
To avoid damage to the electronic components in the heater,
take care to prevent prolonged exposure to driving sources of
water (such as lawn sprinklers, heavy roof runoff, hoses, etc.).
Avoid operation in persistent, extreme, moist or salty
environments.
In extreme weather, shut down the heater and disconnect the
power to it until the weather has moderated. In areas subject
to hurricanes or very high winds, purchase the Bolt Down
Bracket Kit, P/N 460738, see
Figure 16
.
SHEET
METAL
BLOCKS
Hollow masonry blocks, not less than 100 mm (4 in) thick, (laid with ends unsealed and joints
matched for air circulation). Cover blocks with 0.75 mm (0.03 in) minimum galvanized sheet metal.
150 mm
(6 in) Min.
BASE FOR USE ON
COMBUSTIBLE FLOORS
150 mm
(6 in) Min.
Masonary blocks
100 mm (4 in) thick minimum
Lead
Anchor
For Heater mounting
bolts and clamps,
purchase separately
Bolt Down Bracket Kit,
Part No. 460738.
Figure 15.
.
Figure 16.
Section 2. Installation
Содержание MASTERTEMP MT200HD
Страница 50: ...MASTERTEMP Pool and Spa Heater Installation and User s Guide P N 475106 Rev D 1 2016 42 Section Notes...
Страница 51: ...P N 475106 Rev D 1 2016 MASTERTEMP Pool and Spa Heater Installation and User s Guide 43 Notes...
Страница 156: ...Zwembad en spaverwarmingsapparaat MASTERTEMP P N 475106 Rev D 1 2016 42 Hoofdstuk 5 Vervangingsonderdelen Opmerkingen...
Страница 158: ...Zwembad en spaverwarmingsapparaat MASTERTEMP P N 475106 Rev D 1 2016 44 Hoofdstuk 5 Vervangingsonderdelen Opmerkingen...