background image

8

 

AQUALUMIN

®

 III Nicheless Pool Light Installation Guide

 

IMPORTANT NOTICE

This AquaLumin III pool light will install only with the following AquaLumin III pool
light Mounting Brackets, manufactured after JUNE 6, 1994.

D A N G E R !

RISK OF ELECTRICAL SHOCK OR ELECTROCUTION

This Nicheless light fixture must be installed by a licensed or certified electrician or
a qualified pool service person in accordance with the current National Electrical
Code and all applicable local codes and ordinances. Improper installation will
create an electrical hazard which could result in death or serious injury to pool
users, installers or others due to electrical shock and may also cause damage to
property. Always disconnect power to the pool light at the circuit breaker before
servicing the light. Failure to do so could result in death or serious injury to ser-
viceman, pool users or others due to electrical shock.

Section 2: Replacing light fixture in existing pools

    Description

   Part Number

AquaLumin III Vinyl Mounting Bracket Assembly 1"

  78887800

AquaLumin III Vinyl Mounting Bracket Assembly 3/4"   78887700

A. The following are preparatory steps which must be completed by the electrician or

qualified pool service person before replacing light fixture, see Figure 7 on page 9.

1.

Verify the pool meets the requirements of the current National Electrical Code and all local
codes and ordinances. A licensed or certified electrician must install the electrical system to
meet or exceed those requirements before the Nicheless Light is installed. Some of the
requirements of the current National Electrical Code which the pool's electrical system must
meet are as follows:

a.

The lighting circuit must have a Ground Fault Circuit Interrupter (GFCI), and an
appropriately rated circuit breaker.

            WARNING: 

Use only the special stainless steel captive screw (see 

Light

Assembly Parts

, item 4, on page 15) provided with this AquaLumin

®

 III Pool Light. This

screw mounts and electrically grounds the housing securely to the Nicheless fixture.
Failure to use the screw provided could create an electrical hazard which could result in
death or serious injury to pool users, installers or others due to electrical shock.

Содержание AQUALUMIN III

Страница 1: ...ng light fixture in existing pools 7 3 Replacing a lamp only 10 Parts List Replacement Part Kits 13 15 Minimum Qualifications Licensed or Certified Electrician Electrician or qualified pool person Qua...

Страница 2: ...ause a an electrical hazard resulting in death or serious injury to pool users installer or others due to electrical shock or b breakage of the lamp or lens which likewise could result in serious inju...

Страница 3: ...y a licensed or certified electrician or a qualified pool service person in accordance with the current National Electrical Code and all applicable local codes and ordinances Improper installation wil...

Страница 4: ...ding wire must be installed through the conduit from the Junction Box to the bonding grounding lug on the mounting bracket see Figure 3 Seal the wire lug connection with a listed sealant such as 3M Sc...

Страница 5: ...over hole with the word TOP at the top and secure with mounting flange and two 2 hex nuts and lock washers Tighten hex nuts evenly with equal torque When non metallic conduit PVC is used a No 8 AWG bo...

Страница 6: ...the remaining cord through the conduit hole in the mounting hub Place hook mounting bracket over the pin on the bottom of the mounting bracket and press down lightly to secure in place Secure at the...

Страница 7: ...t and light fixture during new vinyl pool construction Continued WARNING Never operate the AquaLumin III Nicheless Pool Light for more than 10 seconds unless it is totally submerged in water Without t...

Страница 8: ...III Vinyl Mounting Bracket Assembly 1 78887800 AquaLumin III Vinyl Mounting Bracket Assembly 3 4 78887700 A The following are preparatory steps which must be completed by the electrician or qualified...

Страница 9: ...lectrical system meets allapplicablerequirements 3 Install this light fixture only in a Pentair Aquatic Systems mounting bracket Mounting brackets made by other manufacturers may not provide proper bo...

Страница 10: ...pin on the bottom of the mounting bracket and press down lightly to secure into place Secure at top of the light with the captive screw 7 Cut the cord at the junction box leaving at least six 6 inches...

Страница 11: ...the deck on a flat soft clean surface Take care not to scratch the lens 4 Using a Phillips head screwdriver loosen do not remove all ten 10 screws on the back of the light 5 Using a Phillips head scr...

Страница 12: ...12 Reinstall the lens gasket lens and plastic face ring While replacing the lens be sure the tabs around the perimeter of the lens gasket are not under the flange of the lens Orientate the lens so th...

Страница 13: ...the pool for servicing NOTE Leave 2 to 3 of slack cord at the top so that the light may be tipped back for removal 17 Feed the remaining cord through the conduit hole in the mounting hub Place the hoo...

Страница 14: ...t assembly 2 619548 Metal bracket cup assembly 3 619549 Mounting hub 3 4 in assembly 4 619550 Mounting hub 1 in assembly 5 78872600 Mountingspacer 6 619617 Housingspacer 7 86001800 Nipple 1 in 8 78887...

Страница 15: ...ption AquaLumin III Replacement Parts Note Sold in Bulb Replacement Kits 600139 and 600138 Lens Replacement Kit 600141 600138 Bulb replacement kit 120V 250W 619484 Bulb 120V 250W Qty 1 619599 Lens gas...

Страница 16: ...re trademarks of 3M Company Corporation Unless expressly noted names and brands of third parties that may be used in this document are not used to indicate an affiliation or endorsement between the ow...

Отзывы: