manualshive.com logo in svg
background image

AMERBRITE

™ 

White LED Pool Lamp Installation and User’s Guide

Be sure that the pool or spa meets the requirements of the current
National Electrical Code (N.E.C.) Article 680-22 and all local codes

and ordinances. A licensed or certified electrician must install the electrical system to
meet or exceed those requirements before the underwater light is installed. Some of
the requirements of the National Electrical Code which the pool’s electrical system
must meet are as follows:

The lighting circuit has a Ground Fault Circuit Interrupter (GFCI) for 120

VAC line voltage models, and has an appropriately rated circuit breaker.
The conductors on the load side of the GFCI circuit shall not occupy
conduit, boxes, or enclosures containing other conductors unless the
additional conductors are also protected by a GFCI. Refer to local codes
for complete details.

The Junction Box (or, for 12 volt models, the low voltage transformer) is

located at least eight (8) inches (20.3 cm) above water level and at least
48 inches (1.22 m) from the edge of the pool. See Figure 1 below.

The light fixture and all metal items within five (5) feet (1.524 m) of the

pool are properly electrically bonded.

The wet niche is properly electrically bonded and grounded via the No.

8 AWG ground connector located at the rear of the niche; see Figure 1.

The wet niche is properly installed so that the top edge of the

underwater light’s lens is at least 18 inches below the surface of the
water in the pool; see Figure 1.

The Amerlite

®

 Light niche must be properly installed so that the top

edge of the AmerBrite

 Light’s lens is at least 18” below (not more than

48 inches (1.22 m) below in Canada) the surface of the water in the pool
or spa.

Be certain that the pool or spa electrical system meets all applicable

requirements, the electrician should also consult the local building
department.

BEFORE REPLACING THE AMERLITE

®

 INCANDESCENT

LIGHT READ THE FOLLOWING INFORMATION

Figure 1

2

Содержание AMERBRITE

Страница 1: ...nstallation and User s Guide IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS INSTALLATION AND USER S GUIDE AMERBRITE UNDERWATER WHITE LED POOL LAMP FOR USE ONLY...

Страница 2: ...amps Using a Wall Switch 1 Operating AmerBrite White LED Lamps Using Control System 1 Using an External Transformer for Multiple AmerBrite 12 VAC Lamps 1 Maximum Wattage using Multiple AmerBrite White...

Страница 3: ...lectric shock When installing and using this electrical equipment basic safety precautions should always be followed include the following RISK OF ELECTRICAL SHOCK OR ELECTROCUTION This underwater lig...

Страница 4: ...restored If the GFCI fails to operate in this manner the GFCI is defective If the GFCI interrupts power to the light without the test button being pushed a ground current is present indicating the pos...

Страница 5: ...mer for Multiple 12 VAC AmerBrite Lamps When using a 300 Watt UL Listed transformer set at 14 VAC with multiple 12 VAC AmerBrite lamps it is recommended that no more than four 4 AmerBrite lamps be use...

Страница 6: ...Box or for 12 volt models the low voltage transformer is located at least eight 8 inches 20 3 cm above water level and at least 48 inches 1 22 m from the edge of the pool See Figure 1 below The light...

Страница 7: ...l hazard resulting in death or serious injury to pool users installers or others due to electrical shock or b breakage of the lamp or lens which could result in serious injury to pool users installers...

Страница 8: ...the light assembly from the niche by tilting the top away from the niche and then lifting the light assembly from the locking tab at the bottom of the niche 4 Place the light assembly on the pool deck...

Страница 9: ...ainless Steel Light housing Be sure the LED assembly is level with the lamp housing CAUTION If the LED assembly is not level the LED assembly may interfere with the lens installation and or have impro...

Страница 10: ...Rotate the face ring so the pilot screw hole is aligned in the 12 O clock position with the lens letter N or W Note Also verify the TOP position arrow indicator label see page 7 on the rear of the ho...

Страница 11: ...t 45 22 Tighten the bolt and nut until the distance between the ends of the clamp equals inch or less 23 Install the special bronze pilot screw at the top of face ring to secure the light to the niche...

Страница 12: ...ction the width of the pool For lights located either end of the pool rotate the lens to the narrow N angle light beam position for increased underwater light intensity and distance WIDE ANGLE LIGHT B...

Страница 13: ...de 9 AmerBrite White LED Pool Lamp Illustrated Replacement Parts View Note A 120 VAC to 12 VAC external transformer is required for the 12 VAC model AmerBrite white pool lamp See page 1 for more infor...

Страница 14: ...ent 620065Z Kit Disc Assy AmerBrite White 120 12V 500W equivalent 8 620060Z Kit stem transformer assembly 120 VAC AmerBrite 9 620061Z Kit stem harness assembly 12 VAC AmerBrite 10 602070 AmerBrite Lam...

Страница 15: ...AMERBRITE White LED Pool Lamp Installation and User s Guide 11 NOTES...

Страница 16: ...d States and or other countries Unless expressly noted names and brands of third parties that may be used in this document are not used to indicate an affiliation or endorsement between the owners of...

Отзывы: