12. Regeneration Time
Press.the.Extra.Cycle.button..Use.this.display.to.set.the.
Regeneration.Time..This.setting.specifies.the.time.of.day.the.
control.will.initiate.a.delayed,.manually.queued,.or.day.override.
triggered.regeneration..This.option.setting.is.identified.by.“RT”.
in.the.upper.left.hand.corner.of.the.screen..Use.the.Up.and.Down.
buttons.to.adjust.the.value.as.needed.
13. Regeneration Cycle Step Times
Press.the.Extra.Cycle.button..Use.this.display.to.set.the.
Regeneration.Cycle.Step.Times..The.different.regeneration.
cycles.are.listed.in.sequence.based.on.the.valve.type.selected.
for.the.system,.and.are.identified.by.an.abbreviation.in.the.upper.
left-hand.corner.of.the.screen..The.abbreviations.used.are.listed.
below..If.the.system.has.been.configured.with.the.“OTHER”.valve.
type,.the.regeneration.cycles.will.be.identified.as.R1,.R2,.R3,.
R4,.R5,.and.R6..Each.cycle.step.time.can.be.set.from.0.to.199.
minutes..Setting.a.cycle.step.time.to.0.will.cause.the.control.
to.skip.that.step.during.regeneration,.but.keeps.the.following.
steps.available..Use.the.Up.and.Down.buttons.to.adjust.the.value.
as.needed..Press.the.Extra.Cycle.button.to.accept.the.current.
setting.and.move.to.the.next.parameter.
Abbreviation
Cycle Step
BD
Brine Draw
BF
Brine Fill
BW
Backwash
RR
Rapid Rinse
SV
Service
Range:.0-199.minutes
14. Day of Week Settings
Press.the.Extra.Cycle.button..Use.this.display.to.set.the.
regeneration.schedule.for.a.system.configured.as.a.Day.of.Week.
control..The.different.days.of.the.week.are.identified.as.D1,.
D2,.D3,.D4,.D5,.D6,.and.D7.in.the.upper.left-hand.corner.of.the.
display..Set.the.value.to.“ON”.to.schedule.a.regeneration.or.“OFF”.
to.skip.regeneration.for.each.day..Use.the.Up.and.Down.buttons.
to.adjust.the.setting.as.needed..Press.the.Extra.Cycle.button.
to.accept.the.setting.and.move.to.the.next.day..Note.that.the.
control.requires.at.least.one.day.to.be.set.to.“ON.”.If.all.7.days.are.
set.to.“OFF”,.the.unit.will.return.to.Day.One.until.one.or.more.days.
are.set.to.“ON.”
MASTER PROGRAMMING MODE
continued
15. Current Day (Display Code CD)
Press.the.Extra.Cycle.button..Use.this.display.to.set.the.current.
day.on.systems.that.have.been.configured.as.Day.of.Week.
controls..This.setting.is.identified.by.“CD”.in.the.upper.left-hand.
corner.of.the.screen..Use.the.Up.and.Down.buttons.to.select.
from.Day.1.through.Day.7.
16. Flow Meter Type (Display Code FM)
Press.the.Extra.Cycle.button..Use.this.display.to.set.the.type.
of.flow.meter.connected.to.the.control..This.option.setting.is.
identified.by.“FM”.in.the.upper.left-hand.corner.of.the.screen..Use.
the.Up.and.Down.buttons.to.select.one.of.the.7.available.settings.
t0.7
Fleck.3/4".Turbine.Meter
P0.7
Fleck.3/4".Paddle.Wheel.Meter
t1.0
Fleck.1".Turbine.Meter
P1.0
Fleck.1".Paddle.Wheel.Meter
t1.5
Fleck.1.1/2".Turbine.Meter
P1.5
Fleck.1.1/2".Paddle.Wheel.Meter
P2.0
Fleck.2".Paddle.Wheel.Meter
GEn
Generic/Other.Meter
17. Meter Pulse Setting (Display Code K)
Press.the.Extra.Cycle.button..Use.this.display.to.specify.the.
meter.pulse.setting.for.a.non-standard.flow.meter..This.option.
setting.is.identified.by.“K”.in.the.upper.left-hand.corner.of.
the.screen..Use.the.Up.and.Down.buttons.to.enter.the.meter.
constant.in.pulses.per.unit.volume.
18. End of Master Programming Mode
Press.the.Extra.Cycle.button.to.save.all.settings.and.exit.Master.
Programming.Mode.
14 •
Pentair.5600SXT.Softener.System