7. Remote Signal Start
This program step selects the remote signal start. Hours, minutes, and seconds can be changed. When Remote
Signal Start is active, the main screen will display. The options are either Off or set to the desired time.
Use Up or Down buttons to adjust this value.
1.
Press the Extra Cycle button.
2.
8. Display Format
This program step is used to set the desired volume display format. This option must be the same on all system
units. U.S. will display volumes in gallons and is in 12 hour timekeeping. Metric will display volumes in cubic
meters and is in 24 hour timekeeping.
Use Up or Down buttons to adjust this value.
1.
Press the Extra Cycle button.
2.
9. Unit Capacity
This program selects the individual timer’s total capacity of hardness that can be removed. The unit capacity is
measured in grains if in U.S. mode and degrees in Metric mode.
U.S. Range: 9,000 to 9,900,000 Grains (Default = 300,000 Grains)
Metric Range: 90.0 to 199,000.0 Degrees (Default = 300.0 Degrees)
Use the Shift button to select the digit you want to modify.
1.
Use Up or Down buttons to adjust this value.
2.
Press the Extra Cycle button.
3.
Master Programming Guide
CAUTION: Before entering Master Programming, please contact your local professional water dealer.
Example of setting Remote Signal Start to 6 minutes.
The display counts down to 0. If Remote Signal Start is
detected for 6 minutes, it will remotely signal start.
Содержание 3200NXT
Страница 1: ...3200NXT Service Manual IMPORTANT Fill in Pertinent Information on Page 3 for Future Reference...
Страница 25: ...Page 25 Notes...
Страница 30: ...Page 30 2750 2850 3150 Input Output Wiring...
Страница 31: ...Page 31 2900 3900 Input Output Wiring...
Страница 34: ...Page 34 Notes...
Страница 35: ...Page 35 Notes...
Страница 36: ...P N 42599 Rev C 4 09...