Master Programming Mode Flow Chart
CAUTION: Before entering Master Programming, please contact your local professional water dealer.
SYSTEM TYPE: 4
SINGLE UNIT
Options:
System 4 (single unit)
System 5 (2-4 units)
System 6 (2-4 units)
System 7 (2 units)
System 9 (2-4 units)
VALVE ADDRESS:
#2
Options:
Valve Address #1 (First Control Valve)
Valve Address #2 (Second Control Valve)
(Default)
Valve Address #3 (Third Control Valve)
Valve Address #4 (Fourth Control Valve)
Example:
System Type 4, Single Unit
Example:
Valve Address #2 (Second Control Valve)
(Default)
SYSTEM SIZE:
2 VALVES
Options:
2 Valves in the System
(Default)
3 Valves in the System
4 Valves in the System
Range:
2 to 4 Valves in the System
Example:
2 Valves in the System
(Default)
REGEN TRIGGER:
TIME CLK DELAYED
Options:
Time Clock Delayed (System 4 Only)
(Default)
Meter Immediate (All System Types)
Meter Delayed Fixed Reserve (Systems 4 & 6 Only)
Remote Signal Start Immediate (All System Types)
Example:
Time Clock Delayed
(Default)
VALVE TYPE:
2750
Options:
2750
(Default)
2850
2900
3150
3900
Stager - Butterfly
Stager - Notch Cam
Example:
2750
(Default)
NOTE: This screen will not display for
System Type 4.
NOTE: This screen will not display for
System Type 4.
NOTE: This screen will only display on
the lead unit for System Types 6 & 7.
For all other System Types, it will display
for all units.
REGENERANT FLOW:
DOWNFLOW
Options:
Downflow
(Default)
UF Brine Draw
UF Fill First
Example:
Downflow
(Default)
REMOTE SIGNAL
START: 00:06:00
Options:
00:06:00
(Default)
Range:
1 second to 99 minutes (1 hour, 39 minutes)
Example:
06:00:00
(Default)
(Hours:Minutes:Seconds)
DISPLAY FORMAT:
US-GALLONS
Options:
U.S. - Gallons
(Default)
European Units - Cubic Meters (Metric)
NOTE: In U.S. - Gallons mode, the display will be in 12-hour time.
NOTE: In European Units - Cubic Meters (Metric) mode, the display will
be in 24-hour time.
Example:
U.S. Gallons
(Default)
UNIT CAPACITY:
00000000 GRAINS
Options:
Grains (in U.S. Format)
(Default)
Degrees (in Metric Format)
Range:
9,000 to 9,900,000 Grain Capacity in U.S. Format
90.0 to 190,000 Degree Capacity in Metric Format
NOTE: The word “GRAINS” will change to “DEGREES” in the metric
Display Format. Use the Shift button to move to the left.
Example:
Grains
(Default)
CAPACITY SAFETY
FACTOR: 00%
Range:
0 to 50%
NOTE: Use the Shift button to move to the left.
Example:
00%
(Default)
FEED WATER
HARDNESS: 15 GPG
Range:
1 to 199 Grains/Gallon (U.S. Format)
2 to 199 Degrees (Metric Format)
NOTE: Use the Shift button to move to the left.
Example:
15 GPG (U.S. Format)
(Default)
REGENERATION DAY
OVERRIDE:OFF
Example:
Off
(Default)
REGENERATION DAY
OVERRIDE:01 DAYS
Options:
Off
(Default)
or On
Range:
1 to 99 Days
Example:
1 Day
CYCLE 1 00:00:00
BACK WASH
Example:
Cycle 1 in Back Wash Mode
Options:
Regeneration Cycle Step #1
Regeneration Cycle Step #2
Regeneration Cycle Step #3
Regeneration Cycle Step #4
Regeneration Cycle Step #5
NOTE: Please refer to the “Regenerant Flow Default Cycle Steps & Times”
in the Master Programming Mode section of the manual.
AUXILIARY RELAY:
DISABLED
Example:
Auxiliary Relay is Disabled
Options:
Enabled
Disabled
(Default)
CHEMICAL PUMP:
DISABLED
Example:
Chemical Pump is Disabled
Options:
Enabled
Disabled
(Default)
CPO AUX RELAY
VOLUME: 000 g
Example:
Chemical Pump Auxiliary Relay
Volume at 0 Gallons
Range:
000 to 999 gallons in U.S. Format
0.000 to 9.999 m3 in Metric Format
CPO AUX RELAY
TIME: 00:00:00
Example:
Chemical Pump Auxiliary Relay at 0 Hours,
0 Minutes, & 0 Seconds
Range:
00:00:00 to 02:00:00
FLOW METER:
1.0 PADDLE
Example:
1.0 Paddle Flow Meter
Options:
1.0 Paddle
1.0 Turbine
1.5 Paddle
1.5 Turbine
2.0 Paddle
3.0 Paddle
Generic
MAXIMUM FLOW
RATE: 0000 gpm
Example:
Maximum Flow Rate of 0 gpm
Range:
20 - 2,000 gpm (U.S. Format)
2.0 - 200.0 m3 (Metric Format)
Range:
1 - 99 Gallons (U.S. Format)
0.1 - 09.9 M3 (Metric Format)
Pulses: 1 - 99
PROGRAMMING UNIT
PLEASE WAIT...
Example:
Master Programming Mode is Exiting
REGENERATION
TIME: 02:00AM
Example:
2:00 A.M.
(Default)
Options:
A.M. (U.S. Format)
HR (Metric Format)
NOTE: Regeneration time will not appear unless
Regeneration Day Override is on.
Options:
Gallons (U.S. Format)
Meter3 (Metric Format)
ADD 01 GALLONS
EVERY 001 PULSES
Example:
Add 1 Gallon for Each Pulse in U.S. Format
AUX RELAY OUTPUT
START 1 00:00:00
Example:
Auxiliary Relay Output in Start 1 at
0 hours, 0 minutes, & 0 seconds
Range:
00:00:00 to 18:00:00
AUX RELAY OUTPUT
END 1 00:00:00
Example:
Auxiliary Relay Output in End 1 at
0 hours, 0 minutes, & 0 seconds
Range:
00:00:00 to 18:00:00
NOTE: Only displayed if Auxiliary
Relay is enabled in previous screen.
Auxiliary Relay will only display if
Chemical Pump is OFF for System
Types 6 & 7.
NOTE: If Stager is chosen for Valve
Type, the Regeneration Cycle Step
description will not display.
NOTE: Only displayed on units that
physically have a meter (Lead
always has a meter). Only shown if
Auxiliary Relay is disabled on
System Types 6 & 7.
NOTES: Default flow meter type is
based on the valve type. This screen
will only display on the lead unit for
System Types 6 & 7. All other system
types it will display for all units.
NOTE: Only displayed if “Generic”
is chosen for the flow meter.
NOTE: Only displayed if “Generic”
is chosen for the flow meter.
NOTE: This screen will only display on
the lead unit for System Types 6 & 7.
For all other System Types, it will display
for all units.
Содержание 3200NXT
Страница 1: ...3200NXT Service Manual IMPORTANT Fill in Pertinent Information on Page 3 for Future Reference...
Страница 25: ...Page 25 Notes...
Страница 30: ...Page 30 2750 2850 3150 Input Output Wiring...
Страница 31: ...Page 31 2900 3900 Input Output Wiring...
Страница 34: ...Page 34 Notes...
Страница 35: ...Page 35 Notes...
Страница 36: ...P N 42599 Rev C 4 09...