background image

P/N  190033

2

Rev. G  6-27-03

4.

Allow sufficient space above the filter to remove the filter lid for cleaning and servicing. This distance will vary with the model of
filter you are using. See Table 1 for the required vertical clearance.

5.

Position the filter to safely direct water drainage. Rotate the High Flow™ manual air relief valve to safely direct purged air or
water. Water discharged from an improperly positioned filter or valve can create an electrical hazard as well as damage
property.

6.

Your filter requires one of the following Pentair Pool
Products accessories which must be purchased separately.

a.

Push-Pull valve

b.

Multiport valve

c.

Bulkhead union set

7.

Make all plumbing connections in accordance with local
plumbing and building codes. Filter plumbing connections
are provided with an O-ring seal. To avoid damage to the
O-rings, use only a silicone base lubricant on the O-rings. Do not use pipe joint compound, glue or solvent on the bulkhead
connections.

8.

The maximum working pressure of this filter is 50 psi. Never subject this filter to pressure in excess of this amount - even when
conducting hydrostatic pressure tests. Pressures above 50 psi can cause the lid to be blown off, which can result in severe injury,
death or property damage.

When performing hydrostatic pressure tests or when testing for external leaks of the completed filtration and plumbing
system, ensure that the maximum pressure that the filtration system will be subjected to DOES NOT EXCEED THE
MAXIMUM WORKING PRESSURE OF ANY OF THE COMPONENTS CONTAINED WITHIN THE SYSTEM. In most
cases, the maximum working pressure will be stated on each component of the system.

If doubt exists as to the pressure to which the system will be subjected, install an ASME approved automatic Pressure
Relief or Pressure Regulator in the circulation system for the lowest working pressure of any of the components in the
system.

SECTION II.

FILTER OPERATION.

A. GENERAL INFORMATION.

1.

This filter operates under pressure. When clamped properly and operated without air in the water system, this filter will
operate in a safe manner.

2.

The maximum working pressure of this filter is 50 psi. Never subject this filter to pressure in excess of this amount - even when
conducting hydrostatic pressure tests. Pressures above 50 psi can cause the lid to be blown off, which can result in severe
injury, death or property damage.

When performing hydrostatic pressure tests or when testing for external leaks of the completed filtration and plumbing
system, ensure that the Maximum Pressure that the filtration system will be subjected to DOES NOT EXCEED THE
MAXIMUM WORKING PRESSURE OF ANY OF THE COMPONENTS CONTAINED WITHIN THE SYSTEM. In most
cases, the maximum working pressure will be stated on each component of the system.

If doubt exists as to the pressure to which the system will be subjected, install an ASME approved automatic Pressure
Relief or Pressure Regulator in the circulation system for the lowest working pressure of any of the components in the
system.

3.

The pressure gauge is the primary indicator of how the filter is operating. Maintain your pressure gauge in good working order.

4.

Never operate filter in excess of three (3) minutes without use of diatomaceous earth. Diatomaceous earth is the substance
that filters the water, the filter cloth merely supports the diatomaceous earth. Operating without diatomaceous earth will
damage filter elements and shorten filtering cycles.

Table 1.

Vertical

Model

P/N

Size

Clearance Req. NSF

FNSP 24

180006

24 sq. ft.

48 in.

no

FNSP 36

180007

36 sq. ft.

62 in.

yes

FNSP 48

180008

48 sq. ft.

74 in.

yes

FNSP 60

180009

60 sq. ft.

86 in.

yes

WARNING

Risk of electrical shock or electrocution. Position the filter and High Flow™ manual air relief valve to safely direct water drainage
and purged air or water. Water discharged from an improperly positioned filter or valve can create an electrical hazard that can
cause severe personal injury as well as damage property.

Содержание 180006

Страница 1: ...e 1 a Tap the clamp with a mallet or similar tool to ensure uniform loading during clamp tightening IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS Table of Contents SECTION I FILTER INSTALLATION 1 SECTION II FILTER OPERATION 2 SECTION III TROUBLE SHOOTING 8 SECTION IV TECHNICAL DATA 9 10 WARRANTY 11 Important Notice Attention Installer This manual contains i...

Страница 2: ...nents in the system SECTIONII FILTEROPERATION A GENERALINFORMATION 1 This filter operates under pressure When clamped properly and operated without air in the water system this filter will operate in a safe manner 2 The maximum working pressure of this filter is 50 psi Never subject this filter to pressure in excess of this amount even when conducting hydrostatic pressure tests Pressures above 50 ...

Страница 3: ... a mallet or similar tool to ensure uniform loading and proper seating of the clamp Continue tapping and tightening until the spring coils touch each other Do not tighten beyond this point 6 FollowtheinstructionsinSectionC SYSTEM RESTART INSTRUCTIONS whichfollows 7 The spring coils should be checked at least once per month to ensure that they continue to touch each other indicating that the clamp ...

Страница 4: ... hair and lint strainer pot with water You may have to do this severaltimes d FollowthestepsoutlinedinSectionC SYSTEM RESTART INSTRUCTIONS forsystemstart up e Introduce the slurry of diatomite from the bucket directly into the top of the skimmer With the pump running and the pool skimmer valve open pour the mixture directly into the skimmer The slurry will be drawn into the filter f Your filter is...

Страница 5: ...id Follow the instructions provided with your pump 5 Neverattempttoassemble disassembleoradjustthefilterclampwhilethereispressureinthefilter Releasethetankclamp assembly and remove tank lid Lift out the complete element for washing Care should be taken not to lose or damage the internal air relief located on top of the manifold 6 Using your garden hose thoroughly flush off all contaminated diatomi...

Страница 6: ... SUN The manufacturer cannot assume any responsibility for torn or damaged bags if left in the sun to dry 10 Replace Separation Tank lid and secure Separation Tank lid clamp Follow instructions in Section B CLAMP INSTALLATIONINSTRUCTIONS 11 LeavevalveinnormalFILTERposition 12 FollowinstructionsinSectionC SYSTEMRESTARTINSTRUCTIONStostartupfilter 13 IntroducetherecommendedamountofdiatomiteperSection...

Страница 7: ...anifold to seat it on to the elements Ensure template is not caught or trapped between manifold and element spouts e Replace the two nuts and the two plastic stand offs if equipped f Replace the completed element assembly into the filter tank I CLEANINGTHEINTERNALAIRBLEEDTUBE 1 Rinse the air bleed tube with water to clean away built up debris Normally this is all that is necessary to properly clea...

Страница 8: ...c of diatomite filters D SHORTFILTERRUNS 1 Until the water initially put into the pool has been completely filtered short filter runs are normal In most cases pool owners are dismayed by the undesirable color and appearance of water in a newly filled pool Plaster dust can be responsible for short filter runs requiring frequent cleaning E PRESSUREDROPSONGAUGE 1 If pressure drops on gauge shut off p...

Страница 9: ...e 60 sq ft filter 12 98211400 Nut 1 4 20 plated brass 13 59000500 Spider grid locator 14 58001000 Nut lock hex nylon 15 39010200 O ring tank clamp 470 O D 15a 071439 O ring tank clamp 500 O D 16 190003 Clamp kit 17 195610 Washer small I D 17a 195611 Washer large I D 18 194997 Nut machined 18a 195612 Spring 19 190034 Assy standpipe outlet 24 sq ft filter 19 190035 Assy standpipe outlet 36 sq ft fil...

Страница 10: ... e r a r e t l i f f o t f q s r e p M P G 5 2 f o d e s a b s i e t a r w o l f s i h T N P t f q s t h g i e H M P G H P G r u o h 6 r u o h 8 6 0 0 0 8 1 4 2 7 3 0 6 0 0 6 3 0 0 6 1 2 0 0 8 8 2 7 0 0 0 8 1 6 3 3 4 0 9 0 0 4 5 0 0 4 2 3 0 0 2 3 4 8 0 0 0 8 1 8 4 9 4 0 2 1 0 0 2 7 0 0 2 3 4 0 0 6 7 5 9 0 0 0 8 1 0 6 5 5 0 5 1 0 0 0 9 0 0 0 4 5 0 0 0 2 7 SECTIONIV TECHNICALDATA cont d B FNS PLUS F...

Страница 11: ...Rev G 6 27 03 11 P N 190033 SAVE THESE INSTRUCTIONS ...