C. SYSTEM RESTART INSTRUCTIONS.

1.

Open the High Flow™ manual air relief valve until it snaps into the full open position (this only requires a quarter
turn counter clockwise). 

Opening this valve rapidly releases air trapped in the filter.

2.

Stand clear of the filter tank, then start the pump.

3.

Close the High Flow™ manual air relief valve after a steady stream of water appears.

4.

The system is not working properly if:

 a.  A solid stream of water does not appear within 30 seconds after the pump's inlet basket fills with water.

 b. The pressure gauge indicates pressure before water out-flow appears.

If either condition exists, 

shut off the pump immediately

, open valves in the water return line to relieve pressure,

and clean the air relief valve; see Section II, FILTER OPERATION. If the problem persists, call Customer Service at
(800) 831-7133.

D. COATING THE FILTER ELEMENTS WITH DIATOMACEOUS EARTH.

1.

Push-Pull Valve.

a.

Push handle on valve down with slight twisting motion as far as it will go. Lock upper pin in cap. Open High Flow™

manual air relief valve on the filter. Proceed with steps 2.b to 2.g, below.

2.

Multiport Rotary Valve.

a.

Position valve to FILTER OR VACUUM TO POOL setting. This is your normal flow from the pump through the filter to

the pool. Open the High Flow™ manual air relief valve on the filter. Proceed with steps 2.b to 2.g, below.

b.

Prepare recommended amount of diatomaceous earth by mixing it with water in a bucket until it is the consistency of milk;

see Section E, PREPARING DIATOMITE.

c.

On initial start-up the pump must be primed by filling the hair and lint strainer pot with water. You may have to do this

several times.

d.

Follow the steps outlined in Section C, SYSTEM RESTART INSTRUCTIONS for system start-up.

e.

Introduce the slurry of diatomite from the bucket directly into the top of the skimmer. With the pump running and the

pool skimmer valve open, pour the mixture directly into the skimmer. The slurry will be drawn into the filter.

f.

Your filter is now operational. Note the original starting pressure on the gauge and record it below.

g.

Clean your filter when pressure reads between 10 to 12 psi higher than the original starting pressure. Your filter pressure

reading will increase as it removes dirt from your pool. However, this build-up of pressure will vary due to different
bathing loads, temperature, weather conditions, etc.

h.

MY ORIGINAL STARTING PRESSURE IS ___________ psi (pounds per square inch). I SHOULD BACKWASH AT

__________ psi.

NOTE

If the starting pressure after backwashing the filter or cleaning the elements indicates 4 to 5 psi higher than the normal
starting pressure, the filter elements must be cleaned. Refer to step 1, Section H, CLEANING FILTER ELEMENTS for
instructions.

CAUTION

The following information should be read carefully since it outlines the proper manner of care and operation for your filter system. You can
expect maximum efficiency and life from your filtration system by following these instructions and taking the necessary preventative care.

 WARNING

THIS FILTER OPERATES UNDER HIGH PRESSURE. WHEN ANY PART OF THE CIRCULATING SYSTEM, e.g.,
CLAMP, PUMP, FILTER, VALVE(S), ETC. IS SERVICED, AIR CAN ENTER THE SYSTEM AND BECOME
PRESSURIZED. PRESSURIZED AIR CAN CAUSE THE LID TO BE BLOWN OFF WHICH CAN RESULT IN SEVERE
INJURY, DEATH, OR PROPERTY DAMAGE. TO AVOID THIS POTENTIAL HAZARD, FOLLOW THESE
INSTRUCTIONS.

Содержание 180006

Страница 1: ...e 1 a Tap the clamp with a mallet or similar tool to ensure uniform loading during clamp tightening IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS Table of Contents SECTION I FILTER INSTALLATION 1 SECTION II FILTER OPERATION 2 SECTION III TROUBLE SHOOTING 8 SECTION IV TECHNICAL DATA 9 10 WARRANTY 11 Important Notice Attention Installer This manual contains i...

Страница 2: ...nents in the system SECTIONII FILTEROPERATION A GENERALINFORMATION 1 This filter operates under pressure When clamped properly and operated without air in the water system this filter will operate in a safe manner 2 The maximum working pressure of this filter is 50 psi Never subject this filter to pressure in excess of this amount even when conducting hydrostatic pressure tests Pressures above 50 ...

Страница 3: ... a mallet or similar tool to ensure uniform loading and proper seating of the clamp Continue tapping and tightening until the spring coils touch each other Do not tighten beyond this point 6 FollowtheinstructionsinSectionC SYSTEM RESTART INSTRUCTIONS whichfollows 7 The spring coils should be checked at least once per month to ensure that they continue to touch each other indicating that the clamp ...

Страница 4: ... hair and lint strainer pot with water You may have to do this severaltimes d FollowthestepsoutlinedinSectionC SYSTEM RESTART INSTRUCTIONS forsystemstart up e Introduce the slurry of diatomite from the bucket directly into the top of the skimmer With the pump running and the pool skimmer valve open pour the mixture directly into the skimmer The slurry will be drawn into the filter f Your filter is...

Страница 5: ...id Follow the instructions provided with your pump 5 Neverattempttoassemble disassembleoradjustthefilterclampwhilethereispressureinthefilter Releasethetankclamp assembly and remove tank lid Lift out the complete element for washing Care should be taken not to lose or damage the internal air relief located on top of the manifold 6 Using your garden hose thoroughly flush off all contaminated diatomi...

Страница 6: ... SUN The manufacturer cannot assume any responsibility for torn or damaged bags if left in the sun to dry 10 Replace Separation Tank lid and secure Separation Tank lid clamp Follow instructions in Section B CLAMP INSTALLATIONINSTRUCTIONS 11 LeavevalveinnormalFILTERposition 12 FollowinstructionsinSectionC SYSTEMRESTARTINSTRUCTIONStostartupfilter 13 IntroducetherecommendedamountofdiatomiteperSection...

Страница 7: ...anifold to seat it on to the elements Ensure template is not caught or trapped between manifold and element spouts e Replace the two nuts and the two plastic stand offs if equipped f Replace the completed element assembly into the filter tank I CLEANINGTHEINTERNALAIRBLEEDTUBE 1 Rinse the air bleed tube with water to clean away built up debris Normally this is all that is necessary to properly clea...

Страница 8: ...c of diatomite filters D SHORTFILTERRUNS 1 Until the water initially put into the pool has been completely filtered short filter runs are normal In most cases pool owners are dismayed by the undesirable color and appearance of water in a newly filled pool Plaster dust can be responsible for short filter runs requiring frequent cleaning E PRESSUREDROPSONGAUGE 1 If pressure drops on gauge shut off p...

Страница 9: ...e 60 sq ft filter 12 98211400 Nut 1 4 20 plated brass 13 59000500 Spider grid locator 14 58001000 Nut lock hex nylon 15 39010200 O ring tank clamp 470 O D 15a 071439 O ring tank clamp 500 O D 16 190003 Clamp kit 17 195610 Washer small I D 17a 195611 Washer large I D 18 194997 Nut machined 18a 195612 Spring 19 190034 Assy standpipe outlet 24 sq ft filter 19 190035 Assy standpipe outlet 36 sq ft fil...

Страница 10: ... e r a r e t l i f f o t f q s r e p M P G 5 2 f o d e s a b s i e t a r w o l f s i h T N P t f q s t h g i e H M P G H P G r u o h 6 r u o h 8 6 0 0 0 8 1 4 2 7 3 0 6 0 0 6 3 0 0 6 1 2 0 0 8 8 2 7 0 0 0 8 1 6 3 3 4 0 9 0 0 4 5 0 0 4 2 3 0 0 2 3 4 8 0 0 0 8 1 8 4 9 4 0 2 1 0 0 2 7 0 0 2 3 4 0 0 6 7 5 9 0 0 0 8 1 0 6 5 5 0 5 1 0 0 0 9 0 0 0 4 5 0 0 0 2 7 SECTIONIV TECHNICALDATA cont d B FNS PLUS F...

Страница 11: ...Rev G 6 27 03 11 P N 190033 SAVE THESE INSTRUCTIONS ...

Страница 12: ...P N 190033 12 Rev G 6 27 03 Pentair Pool Products 1620 Hawkins Ave Sanford NC 27330 919 774 4151 10951 West Los Angeles Ave Moorpark CA 93021 805 523 2400 ...

Отзывы: