CLEAN AND CLEAR
®
PLUS Cartridge Filter Installation and User’s Guide
5
D. CLEANING FILTER MANUALLY
1. Turn the pump off, shut off any automatic controls to ensure that the system is not inadvertently
started during servicing.
2. Open the filter High Flow™ Manual Air Relief Valve (and the waste drain valve or plug, if your
system has one).
3. Remove hair and lint strainer pot lid and clean basket. Replace basket and secure lid.
4. Disconnect air relief valve drain hose if installed.
5. Release tank clamp assembly and remove tank lid.
6. Remove top manifold and cartridge element separately.
7. Using a garden hose without a nozzle, direct water spray at cartridge element to dislodge and
wash away accumulated foreign matter. Flush each cartridge inside and out.
8. Lift bottom manifold out of the tank and flush off any debris.
9. Direct water spray to wash out the inside of the tank body. Water and debris will drain out through
the open drain port.
10. Check gasket around outer lip of bottom plate. Gasket must be firmly and evenly set in place. Do
not use petroleum base lubricants to avoid damage to the gasket.
11. Place bottom manifold, 4 cartridges, top manifold and air relief tube in place. Make sure the
spring and standpipe assembly are retained on the top manifold. Ensure the air relief tube stays in
an upright position. This is essential for the maximum air removal from inside the tank.
12. Be certain the O-ring is in position in the lower tank half. Press the filter lid over the lower tank
half and sandwich the O -ring in between.
13. Replace tank top and carefully follow instructions in Section B, Clamp Installation Instructions.
14. Replace drain plug and reinstall air relief valve drain hose if used.
Please heed all manufacturers' posted instructions, warnings and cautions when using
polyhexamethylene biguanide sanitizers or other cartridge filter cleaner solutions.
Failure to remove all oils and cleaning solutions before acid soaking will result in permanent
restriction of water flow through the filter and will cause premature cartridge failure.
The following information should be read carefully since it outlines the proper manner of care
and operation for your filter system. As a result of following these instructions and taking the
necessary preventative care, you can expect maximum efficiency and life from your filtration
system.
Operating the filter system without filter internal components installed can allow air to
accumulate within the filter. Pressurized air can cause the lid to blow off which can result
in severe injury, death or property damage. Always operate filter system with filter internal
components installed.