background image

CLEAN AND CLEAR

®

 PLUS Cartridge Filter Installation and User’s Guide

10

 Item    Part 

    

  No.      No.       Description

  1 

190058  Gauge, pressure, ¼ in.

  2  98209800  High Flow manual air relief valve  
  

 

(HFMARV)

  3  98201200  Hose and retainer clips for  

 

   

 

HFMARV (Optional accy.)

  4  56636900  Spring, compression 

  4 

178616  Spring, compression 

 

1

 

1

 

1

  5  59071000  Manifold, top assy. 

  5 

170026  Manifold, top assy., 240 sq. ft.

 

  5 

170027  Manifold, top assy., 320 & 520 sq. ft. 

 

  6  R173572  Cartridge Element, 240 sq. ft., 4 req.
  6  R173573  Cartridge Element, 320 sq. ft., 4 req.
  6  R173574  Cartridge Element, 360 sq. ft., 4 req.
  6  R173575  Cartridge Element, 420 sq. ft., 4 req.  
   

 

aqua end caps 

  6  R173576  Cartridge Element, 420 sq. ft., 4 req. 

  6  R173577  Cartridge element, 520 sq. ft., 4 req. 

  6  R173578  Cartridge element, 520 sq. ft., 4 req. 

  7 

170030  Air bleed tube assy., 240 sq. ft.

  7  55028500  Air bleed tube assy., 360, 420 sq. ft. 

  7 

170029  Air bleed tube assy., 320 sq. ft. 

  7 

170028  Air bleed tube assy., 420 sq. ft. 

  7  55028400  Air bleed tube assy., 500 sq. ft. 

  7 

178583  Air bleed tube assy., 520 sq. ft. 

  8  56626800  Manifold, bottom 

  8 

170035  Manifold, bottom/pipe assy., outlet 

  8 

170040  Manifold, bottom 

  9  57000300  Gasket, bottom manifold 

  10  39010200  O-ring, tank clamp (.470 O.D.)
  11  190003  Clamp kit, tension control
  12  195610  Washer, small I.D. 

  12a  195611  Washer, large I.D.

 

  13  194997  Nut, machined 

B.  REPLACEMENT PARTS LIST

  Before 11/98

  After 11/98

  Between  11/98 thru 12/00

  After          12/00

  After           3/03

  After           10/04

  Between     11/98 thru 10/04

 

Item   Part

  No.     No.        Description

 13a  195612  Spring 

  14  55035000  Baffle, bulkhead assy. 

  14  190039  Baffle, bulkhead assy. 

  15  86006900  O-ring, bulkhead, lower
  16  98960311  Bulkhead union, (set) 

  16  271096  Bulkhead adapter kit, 2 in. O.D.,   
  

 

white 

  16  270004  Bulkhead adapter kit, 2 in. O.D.,   
  

 

black 

 

16  270100  Bulkhead union kit, 2 in. I.D., black 

 

16  274426  Bulkhead adapter kit, 2 ½ in. x 2 in.  

   

 

I.D., white 

  17  59019200  Pipe assy., outlet 

  17  170035  Pipe assy., outlet/manifold, bottom 

  17  170036  Pipe assy., outlet 

  18  51005000  O-ring for drain plug
  19  86202000  Plug, 1-1/2 in. drain with O-ring
  20  170023  Tank, lid assy., 240 sq. ft.
  20  170024  Tank, lid assy., 320 sq. ft.
  20  178552  Tank, lid assy., 360 sq. ft.
  20  178551  Tank, lid assy., 420 sq. ft. 

  20  178581  Tank, lid assy., 420 sq. ft. 

  20  178550  Tank, lid assy., 500 sq. ft. 

  20  178582  Tank, lid assy., 520 sq. ft. 

  21  178559  Tank, bottom assy. 

  21  178578  Tank, bottom assy. 

  22  86006900  O-ring, bulkhead, upper 



  22  192320  O-ring, bulkhead, upper 

  23  195339  Ring, back-up 

   

171013  Label kit w/ air relief, 240 sq. ft.

   

171014  Label Kit w/ air relief, 320, 420, 520     

   

 

sq. ft.

 

 

192019  Drain plug wrench

   

010126  Filter lid opener tool

Содержание 160301

Страница 1: ...CLEAN AND CLEAR PLUS CARTRIDGE FILTER IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS INSTALLATION AND USER S GUIDE ...

Страница 2: ...it www pentairpool com or www staritepool com for information about Pentair products TABLE OF CONTENTS Important Warnings and Safety Precautions Section I Filter Installation General Information Section II Filter Operation and Cleaning General Information Clamp Installation Instructions System Restart Instructions Cleaning Filter Manually Replacing Filter Cartridges Cleaning the Manual Air Relief ...

Страница 3: ...s when the system is pressurized These actions can cause the filter to separate and could cause severe personal injury or death if they were to strike a person IMPORTANT WARNING AND SAFETY INSTRUCTIONS IMPORTANT NOTICE This guide provides installation and operation instructions for the Clean and Clear Plus Cartridge Filter Consult Pentair Water Pool and Spa Inc with any questions regarding this eq...

Страница 4: ...ed parts immediately e g closure pressure gauge valve s o rings etc 6 Be sure that the filter is properly mounted and positioned according to instructions provided This filter must be installed by a qualified pool serviceman in accordance with all applicable local codes and ordinances Improper installation could result in death or serious injury to pool users installers or others and may also caus...

Страница 5: ...zard as well as damage property 6 Makeallplumbingconnectionsinaccordancewithlocalplumbingandbuildingcodes Filterplumbing connections are provided with an O ring seal If needed use only a silicone base lubricant on the O rings Do not use pipe joint compound glue or solvent on the bulkhead connections Note To seal the valve connections use thread seal tape thread sealant or plumbing paste non petrol...

Страница 6: ...E approved automatic Pressure Relief or Pressure Regulator in the circulation system for the lowest working pressure of any of the components in the system THIS FILTER OPERATES UNDER HIGH PRESSURE WHEN ANY PART OF THE CIRCULATING SYSTEM e g FILTER LID PUMP FILTER VALVES ETC IS SERVICED AIR CAN ENTER THE SYSTEM AND BECOME PRESSURIZED PRESSURIZED AIR CAN CAUSE THE LID TO SEPARATE FROM THE TANK BOTTO...

Страница 7: ...to ensure that the system is not inadvertently started during servicing b Open the High Flow Manual Air Relief Valve c Wait until all pressure is relieved Never attempt to assemble disassemble or adjust the filter clamp while there is any pressure in the filter 2 Be certain the O ring is in position in the lower tank half Place the filter lid over the lower tank half sandwiching the O ring in betw...

Страница 8: ...dly releases air trapped in the filter 2 Stand clear of the filter tank then start the pump 3 Close the manual air relief valve after a steady stream of water appears 4 The system is not working properly if either of the following conditions occur a A solid stream of water does not appear within 30 seconds after the pump s inlet basket fills with water b The pressure gauge indicates pressure befor...

Страница 9: ...embly are retained on the top manifold Ensure the air relief tube stays in an upright position This is essential for the maximum air removal from inside the tank 12 Be certain the O ring is in position in the lower tank half Press the filter lid over the lower tank half and sandwich the O ring in between 13 Replace tank top and carefully follow instructions in Section B Clamp Installation Instruct...

Страница 10: ...age is open by inserting a 5 16 drill bit through the valve body Verify that the O rings are in good condition properly positioned and lubricated with a silicone base lubricant 5 Reinstall the valve stem and cover assembly with a downward and clockwise motion until it snaps into position SECTION III TROUBLESHOOTING A Air entering your filter is dangerous and can cause the lid to blow off Correct a...

Страница 11: ...gers If it turns freely then the pump must be disassembled and the impeller checked to see if it is clogged If it is not frozen or clogged then there is an obstruction in the line between the pool and the pump D The pressure gauge is an important part of the filter system It is your primary indicator of how the system is operating Maintain your pressure gauge in good working order Check the operat...

Страница 12: ...W PRESSURE DROP psi 0 2 4 6 8 10 12 0 20 40 60 80 100 120 140 160 Clean and Clear Plus Cartridge Filters Recommended Flow Rate Product Model Filter Area sq ft Vertical Clearance Flow Rate GPM Turnover Capacity in Gallons Res Comm 6 Hours 8 Hours 12 Hours 160310 CCP240 240 56 in 90 90 31 400 43 200 64 800 160340 CCP320 320 62 in 120 120 43 200 57 600 86 400 160301 CCP420 420 68 in 150 150 54 000 72...

Страница 13: ...CLEAN AND CLEAR PLUS Cartridge Filter Installation and User s Guide 9 SECTION V REPLACEMENT PARTS A ILLUSTRATED PARTS VIEW 11 21 14 15 18 19 17 16 22 1 2 3 7 4 5 6 8 9 20 10 8 17 13 12 23 ...

Страница 14: ...clamp 470 O D 11 190003 Clamp kit tension control 12 195610 Washer small I D 12a 195611 Washer large I D 13 194997 Nut machined B REPLACEMENT PARTS LIST Before 11 98 After 11 98 Between 11 98 thru 12 00 After 12 00 After 3 03 After 10 04 Between 11 98 thru 10 04 Item Part No No Description 13a 195612 Spring 14 55035000 Baffle bulkhead assy 14 190039 Baffle bulkhead assy 15 86006900 O ring bulkhead...

Страница 15: ...NOTES ...

Страница 16: ... Unless expressly noted names and brands of third parties that may be used in this document are not used to indicate an affiliation or endorsement between the owners of these names and brands and Pentair Water Pool and Spa Inc Those names and brands may be the trademarks or registered trademarks of those third parties Because we are continuously improving our products and services Pentair reserves...