1.5.1 Personnel qualifications 

Qualification and protection limits established for operators 
 

OPERATOR QUALIFICATION 

RECOMMENDED 

INDIVIDUAL 

PROTECTION 

MEANS 

Transportation Familiarity 

and 

knowledge of 
chapters: 
- "General  

information " 

- "Description" 
- "Installation" 

Protective shoes 
and gloves 

Installation Qualification 

compliant with 
regulations and 
installation status, 
knowledge of 
installation status 
and familiarity with 
chapters: 
- "General 

information " 

- "Description" 
- "Installation"" 

Protective shoes 
and gloves 

Operation Familiarity 

and 

knowledge of 
chapters: 
- "General 

information " 

- "Description" 
- "Installation" 

Protective shoes 
and gloves and 
protective 
temperature against 
high temperatures 

Maintenance  

Qualification 
acknowledged by 
PENTAIR WATER 
ITALY. Familiarity 
and knowledge of 
chapters: 
- "General 

information " 

- "Description" 
- "Maintenance” 

Protective shoes 
and gloves 

Demolition  

Familiarity and 
knowledge of 
chapters: 
- "General 

information " 

- "Description" 
- "Installation " 

Protective shoes 
and gloves 

 
 

Danger 

 

The machine operates in safety conditions 
if it is used by qualified personnel in 
accordance with the instructions and 
information contained in this manual and 
present on board. 
All the operations referred to in this manual 
should be performed by qualified personnel 
equipped with the protection means 
described in this manual 

 

 

NOTE

 

PENTAIR WATER ITALY shall not be liable 
for accidents if the machine is used from 
non qualified or unauthorised personnel 
and originating from the failure to follow 
the instructions contained in this manual 
and present on the machine board  

 

1.5.2 Special measures 

The use of personnel with a qualification differing from the one 
indicated can endanger the safety of people and/or damage 
the property. 
 
 

1.6 Conventions 

 

1.6.1 Terminological conventions 

The following conventions have been adopted throughout the 
manual 

Machine 

: electropumps specified in section 

"Product specifications" 

Authorised technician 

: person authorised by PENTAIR 

WATER ITALY to perform even 
the operations not specifically 
indicated in this manual 

Specialised technician 

:  person authorised to perform even 

the operations not specifically 
indicated in this manual after 
being authorised by PENTAIR 
WATER ITALY 

 

1.6.2 Typesetting conventions 

 

Danger 

 

Danger signs indicate procedures that have 
to be thoroughly followed to avoid causing 
physical injuries to operators  

 

Warning 

 

Warning signs indicate procedures that 
have to be thoroughly followed to avoid 
damaging the machine or other equipment 
connected to it  

 

NOTE

 

Notes contain important information that 
are highlighted outside the text and 
connected to it 

 

1.7 Recommended use 

 

1.7.1 Recommended use 

The machine has been designed, manufactured and protected 
to allow the transfer, circulation and increase of pressure of the 
following types of liquid: 
- Water with a temperature ranging from -20 °C to 130 °C (for 

temperatures below 0 °C, it is necessary to add an 
appropriate amount of anti-frost) 

- Cooling fluids that do not contain mineral oils 
- Neutral, non explosive and non aggressive fluids free from 

solid particles and suspended fibres 

The machine has been designed, manufactured and protected 
to guarantee a flow rate of fluid that changes according to the 
desired head (see “Product specifications”). 

 

1.7.2 Recommended installation 

The machine has been designed, manufactured and protected 
to be installed in the following environments: 
- Indoors 
- Outdoors with protection against atmospheric agents 
The machine has been designed, manufactured and protected 
to be used in the following atmospheric conditions: 
- Temperature range: -15 °C and +40 °C 

Relative humidity range: from 30% to 90% 

Содержание Nocchi R2T

Страница 1: ...GB Use and maintenance manual F Manuel d utilisation et d entretien D Bedienungs und Wartungsanleitung E Manual de uso y manutenci n NL Handleiding voor gebruik en onderhound RUS Bycnherwbb gj ecnfyj...

Страница 2: ...iability 3 INSTALLATION Page 17 3 1 Lifting 3 1 1 Machine without any type of packing 3 1 2 Machine packed in a cardboard box 3 2 Transportation 3 3 Storage 3 3 1 Characteristics of the storage area 3...

Страница 3: ...ification data 1 3 Machine identification data Machine code R 2 T D 65 60 X 6 Circulating pump 2 two pole motor 4 four pole motor Coupling to standard motor Twin type Rated diameter of mouths Max head...

Страница 4: ...he property 1 6 Conventions 1 6 1 Terminological conventions The following conventions have been adopted throughout the manual Machine electropumps specified in section Product specifications Authoris...

Страница 5: ...Fax 050 70 31 37 1 11 How to use the documentation supplied Operators should carefully read the documentation supplied before performing any operation on the machine The documentation supplied should...

Страница 6: ...ace with a capacity above the weight of the machines stored Protection against accidental impacts 3 3 2 Environmental characteristics of the storage area The storage area should have the following env...

Страница 7: ...n a low position to avoid water entering the motor and the bearings See the following figure for reference R4T R2T R4TD R2TD Install the machine on horizontal or vertical pipes on the delivery and ret...

Страница 8: ...be performed by loosening the 1 8 cap on the pump housing Sometimes the air venting operation needs to be repeated several times to completely remove the noise originating from the presence of air in...

Страница 9: ...operation of the machine for an hour If the number of starts stops is above 40 adjust the control equipment in order to reduce the frequency Danger For high temperature fluids it is necessary to allow...

Страница 10: ...using the cut off switch Close the gates on the suction and delivery lines Loosen the screws that fix the terminal block cover Disconnect the wires from the terminal block Remove the supply cable from...

Страница 11: ...The line voltage has been interrupted 2 Burnt fuse 3 No conduction in the starter contacts or faulty coil 4 Burnt fuses in the auxiliary circuit E The machine flow rate is irregular 1 Air present in...

Страница 12: ...Dimensioni e pesi Dimensions and weights Dimensions and poids Abmessungen und Gewichte pag 75 Dimensiones y pesos Afmetingen en gewichten Prestazioni Performances Performances Leistungen pag 76 Presta...

Страница 13: ...5 4 0 4 2 RL4TD 40 30 2 x 0 25 2 x 0 37 1380 2840 2810 2 x 0 55 2 x 0 25 2 x 0 37 2 x 0 75 3 x 230 400 2 x 1 10 2 x 0 25 2 x 0 37 50 1380 1390 2810 2860 1380 1390 2 x 1 10 2 x 1 50 2 x 0 25 2 x 0 75 2...

Страница 14: ...120 RL2TD 50 180 RL4TD 65 30 RL4TD 65 60 RL2TD 65 120 RL2TD 65 180 RL4TD 80 30 RL4TD 80 60 RL2TD 80 120 RL2TD 80 180 RL4TD 100 30 RL4TD 100 60 RL2TD 100 120 80 130 100 14 4 68 343 411 250 281 101 180...

Страница 15: ...Prestazioni Performances Performances Leitungen Prestaciones Prestaties R2T R4T 40 76...

Страница 16: ...Prestazioni Performances Performances Leitungen Prestaciones Prestaties R2T R4T 50 77...

Страница 17: ...Prestazioni Performances Performances Leitungen Prestaciones Prestaties R2T R4T 65 78...

Страница 18: ...Prestazioni Performances Performances Leitungen Prestaciones Prestaties R2T R4T 80 79...

Страница 19: ...Prestazioni Performances Performances Leitungen Prestaciones Prestaties R2T R4T 100 80...

Страница 20: ...Prestazioni Performances Performances Leitungen Prestaciones Prestaties R2TD R4TD 40 81...

Страница 21: ...Prestazioni Performances Performances Leitungen Prestaciones Prestaties R2TD R4TD 50 82...

Страница 22: ...Prestazioni Performances Performances Leitungen Prestaciones Prestaties R2TD R4TD 65 83...

Страница 23: ...Prestazioni Performances Performances Leitungen Prestaciones Prestaties R2TD R4TD 80 84...

Страница 24: ...Prestazioni Performances Performances Leitungen Prestaciones Prestaties R2TD R4TD 100 85...

Отзывы: