20

Check the priming of the pumps

Press again key (12)

    and pump n.1 will begin working; re-press the same key to stop the pump and

check the rotation of the same pump.
Acting on the same keys of the other ones check their rotation.

DANGER

Risk of electrical
discharge.

Cut the voltage and reverse two phases of the switchboard power cable

WARNING

Attention:before checking the priming of the pumps, make sure that their
maximum pressure, reported on the plate of the pumps, is compatible
with the pressure borne by the system and by its devices and that any
safety valve has a intervention  value higher than the maximum pump
pressure

In keeping the valves of all the collections closed there is a risk of electrical discharge.

DANGER

Risk of electrical
discharge.

It is possible, by means of the general switch, to cut the voltage from
the switchboard, open the shutter and bring the switch n.1 to position
TEST and all the others to position EXCLUSION

Close the switchboard and check the voltage; pump n.1 will begin working, check that the circuit pressure reaches
the maximum value. If not, repeat the filling operations of the collection of aspiration to the pump. Repeat the operation
on all the pumps within the unit.

Automatic Starting of the unit (refer to Figs. 1-2-3)

After having forced pressure into the unit through the manual driving of the pump, cut the voltage of the switchboard
by bringing the general switch to 0 (OFF).
From then on, the unit will automatically work according to the quantity of water withdrawn by its use.

Change of the working pressure setup

Our units are set and tested during manufacture and the working pressure is set up according to the characteristic
curve of the motor pumps used. It is however possible to modify the working pressure value by changing the setting
of the pressure switch used (in the case of units PM.... OR PT....) or by changing the set up of the parameters setup
(in the case of units SM.... OR ST....)

OFF

ON

P 1

If only one pump has reverse rotation there is a risk of electrical discharge

DANGER

Risk of electrical
discharge.

Cut the general voltage and reverse the two conductors on the contactor
terminal of the pump in question

1) UNITS WITH PRESSURE SWITCH

WARNING

The calibration values of pressure switches must be between the
minimum and maximum working pressure levels foreseen for the
pumps used in the unit and reported on the plate applied to the pumps
themselves.

WARNING

The switchboard automatically reverses the starting order of the pumps
at the end of each working schedule.

Logic of cyclical inversion (with cyclical inversion enabled)

- units without pilot pump

Every time that the voltage is cut from the switchboard the order of original starting is restored.  Pump n.1 should be
operated first upon first automatic starting, then pump n.2 etc.. After each cycle (stopping of all pumps) the pump
following the last is operated. Each time that a pressure switch is opened the microprocessor chooses the pump
which is set and the first started pump stops.

GB

Содержание Nocchi Pressomat

Страница 1: ...gs und Wartungsanleitung E Manual de uso y manutenci n NL Handleiding voor gebruik en onderhound PL Recyzny uzywaine i obslugi RUS Bycnherwbb gj ecnfyjdrt b Bycnherwbb gj ecnfyjdrt b Bycnherwbb gj ecn...

Страница 2: ...i direktivene gjengitt nedenfor EU VAATIMUSTENMUKAISUUSVAKUUTUS Yhti Pentair International Sarl ilmoittaa omalla vastuullaan ett alla osoitetut tuotteet ovat oleellisten turvallisuus ja terveydensuoj...

Страница 3: ...ely the retailer In case of claims contact immediately the retailer within eight days of purchase Chap 2 Limits of use Our pressurization groups are constructed for the raising clean water without sol...

Страница 4: ...t pressure in the installation or with the tanks disassembled Chap 4 Priming of the group DANGER Risk of electrical discharge Always shut off the voltage before proceeding to any operation WARNING the...

Страница 5: ...Once all the hydraulic and electric connections have been done for the hydraulic priming of the pumps and collectors proceed as follows close all the valves of the distribution system open all the va...

Страница 6: ...to 0 OFF From then on the unit will automatically work according to the quantity of water withdrawn by its use Change of the working pressure setup Our units are set and tested during manufacture and...

Страница 7: ...small collector by bringing the pressure to the level start pump that we want to assign to pressure switch n 1 tighten screw B of pressure switch n 1 to the point where its electric contact closes ON...

Страница 8: ...ped WARNING The calibration values of the pressure switch must be between the minimum and maximum working pressure levels foreseen for the pump used in the unit and reported in the plate applied to th...

Страница 9: ...NO Line n 1 COMPRESSOR With keys 16 or 17 it is possible to set the parameter YES or NO YES means that the unit has a pump and an air compressor operated by the same switchboard In this example NO Li...

Страница 10: ...essage will appear ENTER TIMING PUMPSN 3s 060 Line n 1 Timing Noparameter Line n 2 PUMPS N 3 s With keys 16 or 17 it is possible to set the parameter to any value between 0 and 255 seconds This indica...

Страница 11: ...ollowing message will be displayed In this case both the green led 2 and the red led 5 are lit BEFORETHEBUZZEREMITSTHE8th EIGHTH RING Press key 11 for a few seconds The following message will be displ...

Страница 12: ...ted by the same switchboard In the example NO Line n 2 no message After choosing the parameter press key 18 the following message will appear ENTER DELAY FC S 40 ACTIVATION FC s X60 Line n 1 DELAY FC...

Страница 13: ...pump will be stopped XXX seconds after having reached the maximum pressure set In the case of this example it is for 40 seconds After choosing the parameter press key 18 the following message will app...

Страница 14: ...isplayed M A MANUALE FUNCTION BAR 5 3 The buzzer automatically sounds off and the red led 5 remains turned on Press key 18 for 2 seconds and the following message will be displayed LINEA MAN MAN ENTER...

Страница 15: ...r 17 set the number in tens of minimum pressure values for the second pump normally 0 Confirm by pressing key 18 The cursor will change position depending on the number of units involved With keys 16...

Страница 16: ...BARs normally 0 3 to 1 0 lower than the value assigned to pump 3 Line n 2 MIN0X XS With keys 16 or 17 set the number in tens of minimum pressure value of the fourth pump normally 0 Confirm by pressin...

Страница 17: ...mechanic seal etc it is advisable to provide the machine with devices for the periodic starting of the pump and for the signaling of possible damages These additionally have the followings devices 1 w...

Страница 18: ...ch on I ON Replace the disconnected fuses Press the AUT switch Restore the water level GB Theconnectingtubeofthepressure switches are obstructed The pressure switches cable is by passed The push selec...

Страница 19: ...129 Fig 2 a...

Страница 20: ...130 I Fig 2 b...

Страница 21: ...131 Fig 3...

Страница 22: ...132 Fig 5...

Страница 23: ...133 Fig 4 Fig 6 Fig 7 Fig 8 Fig 9...

Страница 24: ...134 Fig 10...

Страница 25: ...s t correctement effectu s Si la panne est due des causes de force majeure ou d autres facteurs externes et incontr lables Si le produit est utilis avec des liquides abrasifs ou corrosifs ou diff rent...

Страница 26: ...elni a k vetkez iratokat v s rl st igazol sz mla r szletes hibabejelent Niniejsze urz dzenie obj te jest gwarancj prawn zgodnie z przepisami i normami obowi zuj cymi w danym pa stwie w dniu zakupu pok...

Страница 27: ...253P8800 PENTAIR INTERNATIONAL S a r l Avenue de Sevelin 18 1004 LAUSANNE Switzerland...

Отзывы: