24
Warning and Alarm conditions
The IntelliFlo
®
VS alarms and warnings are indicated by flashing LEDs on the control panel. For
example, if a “Drive Temperature” warning occurs, the LED will blink two times, then Off, then
blink two times. This sequence is repeated until the condition is cleared.
•
Warning condition:
If a warning condition occurs the pump will be continue to run but at
a reduced speed. The Green LED executes a sequence of blinks to indicate which alarm or
warning has occurred.
•
Alarm condition:
If an alarm condition occurs the pump will drive stop running. The red
LED flashes continuously to indicate the presence of an alarm. The alarm LEDs will reset
when the condition clears.
Alarm and warning LED sequence
Section 5
Troubleshooting
CAUTION:
Before installing this product, read and follow all warning notices and
instructions.
Number of time the
LED will blink
Alarm
Description
Action
2
Drive Temperature Warning
Excessive drive temperature
1. Ensure the motor fan has
adequate area for ventilation.
2. Stop motor and allow to cool.
3. Run motor at a higher speed to
improve cooling air flow.
5
Unknown alarm
Electron failure
1. Cycle power to reset pump.
2. Replace drive.
6
Drive Temperature Alarm
Excessive drive temperature
1. Ensure the motor fan has
adequate area for ventilation.
2. Run motor at a higher speed to
improve cooling air flow.
7
Power Out Alarm
Supply voltage low
Ensure proper supply voltage.
8
Over current Alarm
Excessive drive current
1. Examine fluid/mechanical
system for source of overload.
2. De-energize motor and
determine if motor spins freely.
3. Replace drive.
9
Over voltage Alarm
Excessive voltage on drive buss
1. Rapid switching between speeds
can cause excessive voltages
on the drive’s DC buss.
2. Ensure proper supply voltage.
English