IntelliBrite
®
5g White Pool Light and White Spa Light Installation and User’s Guide
9
1.
Turn off main electrical switch or circuit breaker
, as well as the switch
which operates the IntelliBrite light itself.
2.
Before starting make sure that you have a new lens gasket (P/N 79101600)
and a IntelliBrite 5g white pool light circuit board assembly (P/N 619875Z -
300w, P/N 619916Z-400W, P/N 619917Z- 500w) ready to install
(see page 15).
3.
REMOVING THE INTELLIBRITE 5G WHITE POOL
LIGHT ASSEMBLY:
Remove the pilot screw at top
of face ring, remove the light assembly from the
niche. Place the assembly on the deck.
Note:
It is
not necessary to drain down the pool.
4.
Unwind the cord from the base of the light housing.
Be sure to keep the pilot screw from the IntelliBrite light. This screw
mounts and electrically grounds the housing securely to the
mounting ring and wet niche. Failure to use the screw provided could create an
electrical hazard which could result in death or serious injury to pool users, installers
or others due to electrical shock.
REPLACING THE INTELLIBRITE 5G WHITE POOL LIGHT CIRCUIT
BOARD ASSEMBLY (IN AN EXISTING POOL)
Replace the light circuit board assembly with the same type and
wattage. Failure to replace the light circuit board assembly with
the same type will damage the light assembly and may cause an electrical hazard
resulting in death or serious injury to pool users, installers, or others due to
electrical shock, and may also cause damage to property.
Removal and Installation of IntelliBrite 5g White Light Circuit Board
D A N G E R !
RISK OF ELECTRICAL SHOCK OR ELECTROCUTION
Always disconnect power to the pool light at the circuit
breaker before servicing the light. Failure to do so could
result in death or serious injury to installer, service person,
pool users, or others due to electrical shock.
When replacing or reassembling the IntelliBrite White Pool Circuit Board,
the Gasket (P/N 79101600) or Gasket and Lens (619864Z) MUST ALSO BE
REPLACED - SEE PAGE 15 FOR PART NUMBERS
Always install a new lens gasket (P/N 79101600) whenever
disassembling the IntelliBrite light assembly. Failure to do so
may permit water to leak into the assembly which could cause:
(a)
an electrical hazard resulting in death or serious injury to pool users,
installers, or others due to electrical shock, or
(b)
breakage of the lens, which likewise could result in serious injury to pool
users, installers, or bystanders, or in damage to property.
IntelliBrite 5g White Pool Light
Pilot screw (bronze)