background image

7

SW/SD/VS25 & 33
Parts List

Ref. No.

Description

Part No.

Qty.

1

Screw – Machine #10 - 24 x 3/8"

114770-006-1

2

2

3

Nameplate

13425-062-1

1

4

Handle – Pump

8522-006-1

1

5

Plug – Pipe

14981-001-1

1

6

7

9

10

Screw – Machine #8

14770-001-1

1

11

Wire Ground

6000-053-1

1

12

Screw – Hex #8-32 (1/4 HP)

145-026-1

2

12

Screw – Hex #8-32 (1/3 HP)

145-009-1

2

13

Screw – Hex, 1/4 & 20

176-005-1

3

14

Seal – Shaft (Stationary Seat)

5484-001-1

1

15

Seal – Shaft (Rotating Seat)

5484-003-1

1

16

Case – Volute

8504-002-2

1

17

Impeller

8498-003-1

1

18

Base – Strainer

8520-002-1

1

19

Plate – Bottom (1/4 HP)

8521-001-1

1

19

Plate – Bottom (1/3 HP)

8521-002-1

1

20

Screw – Machine #10 -24 x 1-1⁄4

27252A001

5

21

22

23

Ring – Seal

149-001-1

1

24

25

Stator (1/4 HP)

14581-001-1

1

25

Stator (1/3 HP)

14590-001-1

1

26

Rotor (1/4 HP) Shaft & Bearing

14581-101-1

1

26

Rotor (1/3 HP) Shaft & Bearing

14590-010-1

1

27

Housing – Motor

8507-013-1

1

29

Shaft

5482-001-1

1

30

31

Cord – Power (SD25A1-10', 

14623-010-1

1

SD33A1-10') SW 

31

Cord – Power (SD25A1-20', 

14623-020-1

1

SD33A1-20') SW 

32

Label

10193-019-1

1

33

Push Mount Tie

1055-001-1

1

34

Float Switch – Wide Angle 

13967-010-1

1

(10' cord)

34

Float Switch – Wide Angle 

13967-020-1

1

(20' cord)

35

Bracket

5502-011-1

1

36

Screw, 10-32 x 1/2

30-021-1

1

37

Lockwasher

995-008-1

1

38

Switch – Diaphragm 

14974-000-5

1

(SD25A1-10', SD33A1-10')

38

Switch – Diaphragm  

14974-001-5

1

(SD25A1-20', SD33A1-20')

39

Bearing

65-024-1

1

41

Cord Nut

75-005-1

1

42

Seal Ring

139-014-1

43

Switch – Vertical (VS25/33 - 10’)

13869-210-5

1

43

Switch – Vertical (VS25/33 - 20’)

13869-220-5

1

Ref. No.

Description

Part No.

Qty.

SW25A and SW33A

MODELS

SD25A and SD33A

MODELS

35

36 37

38

33

34

VS25A and VS33A

MODELS

35

43

Содержание Hydromatic SW25/33

Страница 1: ...SW SD VS25 33 SW25 33 SD25 33 VS25 33 NOTE To the installer Please make sure you provide this manual to the owner of the pumping equipment or to the responsible party who maintains the system Pump In...

Страница 2: ...e strictly adhered to Do not install pump in location classified as hazardous per N E C ANSI NFPA 70 1999 Failure to heed above cautions could result in injury or death General Information Pump Warnin...

Страница 3: ...recommended that the pump s be cycled every month to ensure pumping system is working properly when needed NOTE The Q Alert alarm panel is for indoor use only For applications and products contact yo...

Страница 4: ...wn fuse tripped circuit breaker or a power cord not completely inserted into the receptacle 3 NOTE Automatic thermal overload protects the sealed in oil motor Running dry will overheat the motor and a...

Страница 5: ...be clogged Remove pump and clean out openings 4 Impeller or volute openings may be plugged or be partially plugged Remove the pump and clean per maintenance instructions 5 Pump impeller may be partial...

Страница 6: ...TE TO O W N E R R E P A I R S T A T I O N Clip on dotted line and attach to Warra nty Repa ir Repo rt The clippe d portio n must be attach ed in order to for repair s to be S P M A C er tif ie d 31 30...

Страница 7: ...25 Stator 1 3 HP 14590 001 1 1 26 Rotor 1 4 HP Shaft Bearing 14581 101 1 1 26 Rotor 1 3 HP Shaft Bearing 14590 010 1 1 27 Housing Motor 8507 013 1 1 29 Shaft 5482 001 1 1 30 31 Cord Power SD25A1 10 1...

Страница 8: ...and shipping charges associated with this warranty and must request warranty service through the installing dealer as soon as a problem is discovered No request for service will be accepted if receive...

Отзывы: