background image

Thank you for purchasing your
Hydromatic

®

pump. To help

ensure years of trouble-free
operation, please read the
following manual carefully.

Before Operation:

Read the following instructions
carefully. Reasonable care and
safe methods should be practiced.
Check local codes and
requirements before installation.

Attention:

This manual contains important
information for the safe use of
this product.  Read this manual
completely before using this
product and refer to it often for
continued safe product use.
DO NOT THROW AWAY OR
LOSE THIS MANUAL.  Keep it
in a safe place so that you may
refer to it often.

WARNING: Before handling
these pumps and controls,
always disconnect the power
first. Do not smoke or use 
sparkable electrical devices or
flames in a septic (gaseous) or
possible septic sump.

To reduce risk of electrical shock:

1.

Risk of Electrical Shock:

This pump has not been
investigated for use in 
swimming pool areas.

2. 

Risk of Electrical Shock:

Connect only to a properly
grounded receptacle.

Septic tank to be vented
in accordance with local
plumbing codes.

Do not smoke or use sparkable
electrical devices or flame in a
septic (gaseous) or possible
septic sump.

If a septic sump condition may
exist and if entry into sump is
necessary, then (1) provide
proper safety precautions per
OSHA requirements and (2) 
do not enter sump until 
these precautions are strictly
adhered to.

Do not install pump in location
classified as hazardous per
N.E.C., ANSI/NFPA 70 - 1999.

Failure to heed above  cautions
could result in injury or death.

General
Information

Pump
Warning

Approx. Turn-On Level

SW25A/SW33A 9-

1

/

2

"*

SD25A/SD33A

7-

7

/

8

"

VS25A/VS33A

7-

1

/

2

"

Approx. Turn-Off Level

SW25A/SW33A 3-

1

/

2

"*

SD25A/SD33A

3-

3

/

8

"

VS25A/VS33A

4"

2. Make sure float (Models

SW25A, SW33A & VS25 or
VS33) hangs free. It should
not come into  contact with
side or bottom of sump.

3. Make sure sump is free of

string, cloth, nails, gravel, etc.
before installing pump.

4. Do not set pump directly on

the bottom of sump if it is not
solid.  Raise the pump by
using bricks or concrete blocks
underneath it.

5. Use steel or plastic pipe for all

connecting lines between
pump and sewer outlet.

NOTE: Some city 
regulations do not allow 
installing a pump with 
plastic pipe. Check local
regulations.

6. Hydromatic

check valve

should be installed in 
discharge pipe, at least twelve
inches above the discharge
outlet of the pump.

7. Connect to power source using

3-prong grounded 115 volt 
AC receptacle. Do not 
remove ground pin from 
electrical plug. Do not use an
extension cord.

8. For proper automatic 

operation make sure the pump
power cord is plugged into the
back of the “piggyback” 
receptacle on the switch cord.

These important instructions 
must  be followed for satisfactory
performance of your pump.
Before installation, check 
your local electrical and 
plumbing codes.

1. Provide proper sump.

Minimum Sump Diameter

SW25A/SW33A 18"

SD25A/SD33A

12"

VS25/33A

12"

2

Pump
Installation

Содержание Hydromatic SW25/33

Страница 1: ...SW SD VS25 33 SW25 33 SD25 33 VS25 33 NOTE To the installer Please make sure you provide this manual to the owner of the pumping equipment or to the responsible party who maintains the system Pump In...

Страница 2: ...e strictly adhered to Do not install pump in location classified as hazardous per N E C ANSI NFPA 70 1999 Failure to heed above cautions could result in injury or death General Information Pump Warnin...

Страница 3: ...recommended that the pump s be cycled every month to ensure pumping system is working properly when needed NOTE The Q Alert alarm panel is for indoor use only For applications and products contact yo...

Страница 4: ...wn fuse tripped circuit breaker or a power cord not completely inserted into the receptacle 3 NOTE Automatic thermal overload protects the sealed in oil motor Running dry will overheat the motor and a...

Страница 5: ...be clogged Remove pump and clean out openings 4 Impeller or volute openings may be plugged or be partially plugged Remove the pump and clean per maintenance instructions 5 Pump impeller may be partial...

Страница 6: ...TE TO O W N E R R E P A I R S T A T I O N Clip on dotted line and attach to Warra nty Repa ir Repo rt The clippe d portio n must be attach ed in order to for repair s to be S P M A C er tif ie d 31 30...

Страница 7: ...25 Stator 1 3 HP 14590 001 1 1 26 Rotor 1 4 HP Shaft Bearing 14581 101 1 1 26 Rotor 1 3 HP Shaft Bearing 14590 010 1 1 27 Housing Motor 8507 013 1 1 29 Shaft 5482 001 1 1 30 31 Cord Power SD25A1 10 1...

Страница 8: ...and shipping charges associated with this warranty and must request warranty service through the installing dealer as soon as a problem is discovered No request for service will be accepted if receive...

Отзывы: