background image

Item # E-03-472  2/07

Part # 5625-472-1 

WARRANTY

Hydromatic

®

warrants to the original purchaser of each Hydromatic product(s) that any part

thereof that proves to be defective in material or workmanship within one year from date of installation or 
18 months from manufacture date, whichever comes first, will be replaced at no charge with a new or 
remanufactured part, F.O.B. factory. Purchaser shall assume all responsibility and expense from removal,
reinstallation and freight. Any item(s) designated as manufactured by others shall be covered only by the 
express warranty of the manufacturer thereof. This warranty does not apply to damage resulting from
accident, alteration, design, misuse or abuse. The pump must be installed, operated and maintained in 
accordance with the published instructions of the appropriate Installation & Service Manual.

All dual seal non-clogs and 3–5 HP grinders must have seal failure and heat sensors attached and functional

for Warranty to be in effect. If a seal failure should occur, Hydromatic will cover only the lower seal and labor
thereof. Labor is based on Authorized Service Center contract allowance. If the heat sensor is not attached
and functional, Warranty is void. If the seal failure sensor is not attached and functional, Warranty is void.

If the material furnished to the Buyer shall fail to conform to this contract or to any of the terms of this 

written warranty, Hydromatic shall replace such nonconforming material at the original point
of delivery and shall furnish instruction for its disposition. Any transportation charges involved in such
disposition shall be for the Buyer’s account. The Buyer’s exclusive and sole remedy on account or in respect
of the furnishing of material that does not conform to this contract or to this written warranty, shall be to 
secure replacement thereof as aforesaid. Hydromatic shall not in any event be liable for the cost of any labor
expended on any such material or for any incidental or consequential damages to anyone by
reason of the fact that such material does not conform to this contract or to this written warranty.

ALL IMPLIED WARRANTIES, INCLUDING THE IMPLIED WARRANTY OF MERCHANTABILITY

AND THE IMPLIED WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE, ARE DISCLAIMED
TO THE SAME EXTENT AS THE EXPRESS WARRANTY CONTAINED HEREIN. Some states do not
allow limitations on how long an implied warranty lasts, so the above limitation may not apply to you.

MANUFACTURER EXPRESSLY DISCLAIMS AND EXCLUDES ANY LIABILITY FOR 

CONSEQUENTIAL OR INCIDENTAL DAMAGES FOR BREACH OF ANY EXPRESS OR IMPLIED
WARRANTY ARISING IN CONNECTION WITH THIS PRODUCT, INCLUDING WITHOUT 
LIMITATION, WHETHER IN TORT, NEGLIGENCE, STRICT LIABILITY CONTRACT OR 
OTHERWISE. Some states do not allow the exclusion or limitation of incidental or consequential damages,
so the above limitation or exclusion may not apply to you. This warranty gives you specific legal rights, and
you may also have other rights which vary from state to state.

– Your Authorized Local Distributor –

USA

740 East 9th Street, Ashland, Ohio 44805

Tel: 419-289-3042  Fax: 419-281-4087

www.hydromatic.com

CANADA

269 Trillium Drive, Kitchener, Ontario, Canada N2G 4W5

Tel: 519-896-2163  Fax: 519-896-6337

© 2007 Hydromatic

®

Ashland, Ohio. All Rights Reserved.

Содержание Hydromatic S4HRC

Страница 1: ...For use with product built with USEM motor S4HRC NOTE To the installer Please make sure you provide this manual to the owner of the pumping equipment or to the responsible party who maintains the sys...

Страница 2: ...the seal failure unit indicates only that there is some water in the seal chamber The pump will continue to operate without damage but the seal should be checked immediately after failure is indicate...

Страница 3: ...ludes a maincircuit breaker for each pump a magnetic starter with overload protection for each pump an H O A switch and run light for each pump an electric alternator and a transformer to provide appr...

Страница 4: ...o the sump and cause short cycling of the pump NEMA 4 Junction Box Optional If electrical control panel is to be set remote from the pump sump a NEMA 4 junction box should be used to make power and co...

Страница 5: ...CORD See Wiring Diagram of seal failure unit 4673 or 4674 for connecting dark green and red wires If seal fail ure unit 4673 or 4674 is not used leave dark green and red wires open CONNECTION DIAGRAM...

Страница 6: ...ration 6 Turn both H O A switches to OFF position and allow sump to fill to the override control level 7 Turn both switches to Auto position and both pumps should start and operate together until leve...

Страница 7: ...r is present seals can be considered satisfactory to reuse 9 Check top bearing If clean and does not turn rough bearings can be reused and it is not necessary to completely dismantle pump to change be...

Страница 8: ...ut seal with screwdriver 8 To remove seal housing take out socket head bolts and using bolts in back of holes pry plates loose This will force out the lower seal if not already removed 9 Remove snap r...

Страница 9: ...the closed position Check in sump to be sure control is free 3 Selector switch may be in the Hand position Pump does not deliver proper capacity 1 Discharge gate valve may be partially closed or part...

Страница 10: ...ng Plate 1 15 001780041 SHCS 5 16 18 UNC x 1 4 16 000650311 Lower Ball Bearing R 1 17 009200011 Upper Mechanical Seal 1 18 19103A062 HHCS 1 2 13 UNC x 3 4 19 001500241 O Ring SC 2 20 009240101 Pipe Pl...

Страница 11: ...11 S4HRC...

Страница 12: ...isposition Any transportation charges involved in such disposition shall be for the Buyer s account The Buyer s exclusive and sole remedy on account or in respect of the furnishing of material that do...