10
IntelliFlo
®
Pump Demo Kiosk Operation and Set-Up Instructions
Water Fill and Priming
1. Be sure the Flow Valve on discharge piping is OPEN (lever
90° to pipe).
2. Add water to the system by removing the top lid of the pump
and filling the pump stainer basket with water.
3. Add water until the water level in the tub is 2” to 3” from the
top lip. Securely fasten the lid after the tub is full.
4. Check the water level periodically - water can evaporate over
time. Be sure the water level in the tub is at least half full.
Start Up Sequence
1. Switch ON the transformer (red light means power is on). Be sure switch on power strip is ON.
2. Switch the DAQ-202 “Black Box” Unit ON. The keypad will light up on the pump.
3. Be sure to read important instructions above. Turn the pump ON. (Press Stop/Start button on pump keypad).
Look for any sign of leaking water. If this occurs, press the Stop/Start button to turn the pump off.
4. Look inside the kiosk and inspect flexible connections for leaks. If leaks are found, press the Stop/Start button
on the pump keypad, tighten loose connections, and resume start up.
5. Turn the monitor ON (
Note: Turn on monitor before turning on the computer).
6. Turn the wireless mouse ON.
7. Turn on computer. The computer should automatically boot up into pump start up screen. If LCD monitor
screen does not display in full screen, verify screen settings are set to 1440 x 900. (See troubleshooting on
page 18 for more information).
Start Up and Operation
Valve Open
Valve Closed
DO NOT ADD ADDITIONAL WATER AFTER THE INITIAL START-UP.
Water in pipes could drain downward and cause an overflow into the water tub and cabinet.
IMPORTANT! READ BEFORE TURNING ON THE PUMP
Pump can draw up to 3000 watts of power during priming and start up (typical 120V
20 Amp circuit is limited to 1800 watts maximum). Check to be sure the pump watt and
power usage does not exceed the rated capacity of the electrical outlet.
For continued, safe operation,
set the pump’s maximum speed prior to operation.
The pump should not run on a high speed for an extended length of time.
Refer to the IntelliFlo
®
installation and user’s manual for instructions on how to set the
pump’s maximum speed.