Pump Demo Kiosk Operation and Set-Up Instructions 

Water Fill and Priming

1.  Be sure the Flow Valve on discharge piping is OPEN (lever 

90° to pipe).  

2.  Add water to the system by removing the top lid of the pump 

and filling the pump stainer basket with water. 

3.  Add water until the water level in the tub is 2” to 3” from the 

top lip. Securely fasten the lid after the tub is full.

4.  Check the water level periodically - water can evaporate over 

time. Be sure the water level in the tub is at least half full. 

Start Up Sequence

1.  Switch ON the transformer (red light means power is on). Be sure switch on power strip is ON. 

2.  Switch the DAQ-202 “Black Box” Unit ON. The keypad will light up on the pump. 

3.  Be sure to read important instructions above. Turn the pump ON. (Press Stop/Start button on pump keypad). 

Look for any sign of leaking water. If this occurs, press the Stop/Start button to turn the pump off. 

4.  Look inside the kiosk and inspect flexible connections for leaks. If leaks are found, press the Stop/Start button 

on the pump keypad, tighten loose connections, and resume start up. 

5.  Turn the monitor ON (

Note: Turn on monitor before turning on the computer).

6.  Turn the wireless mouse ON.

7.  Turn on computer. The computer should automatically boot up into pump start up screen. If LCD monitor 

screen does not display in full screen, verify screen settings are set to 1440 x 900.  (See troubleshooting on 
page 18 for more information).

Start Up and Operation 

Valve Open

Valve Closed

DO NOT ADD ADDITIONAL WATER AFTER THE INITIAL START-UP. 
Water in pipes could drain downward and cause an overflow into the water tub and cabinet.

IMPORTANT! READ BEFORE TURNING ON THE PUMP

Pump can draw up to 3000 watts of power during priming and start up (typical 120V 
20 Amp circuit is limited to 1800 watts maximum). Check to be sure the pump watt and 
power usage does not exceed the rated capacity of the electrical outlet.
For continued, safe operation, 

set the pump’s maximum speed prior to operation. 

The pump should not run on a high speed for an extended length of time.
Refer to the IntelliFlo

®

 installation and user’s manual for instructions on how to set the 

pump’s maximum speed. 

Содержание DAQ-202

Страница 1: ...IntelliFlo Pump Demo Kiosk Operation and Set Up Instructions Pre Installed Live Pump Demo...

Страница 2: ...nt is subject to change without notice IntelliFlo and Pentair Water Pool and Spa are trademarks and or registered trademarks of Pentair Water Pool and Spa Inc and or its affiliated companies in the Un...

Страница 3: ...s Shipping Contents Quick Reference Guide Connection Diagram Cabinet Set Up Front Handle Installation Base Cabinet and Pump Module Assembly Connecting Pump to Power Supply Installing the Piping Gray P...

Страница 4: ...ischarge Lo Pressure TDH pump suction LEGEND LO HI ON OFF FLOW PRESSURE Step Up Transformer 120V 240V Laptop 19 LCD Monitor Power Up Sequence 1 Main 120V Supply ON 2 Transformer ON 3 Black Box On 4 Mo...

Страница 5: ...sembly includes IntelliFlo pump Threaded union adapters attached to pump Pump mounted on mounting board LCD monitor stand Power cord Front Handle Assembly Using a Philips head screw driver attach the...

Страница 6: ...low Assembly into the clear pipe end of the assembly 3 Start by placing the tasselled end into the opening and continue by pushing into the pipe until the metal ring is flush out inside the gasket see...

Страница 7: ...Slide the water tub lid and pipes into the open area on the left side of the kiosk cabinet with the 1 1 2 suction pipe section facing toward the front Installing White PVC Piping Inside Cabinet Flexi...

Страница 8: ...EGEND LO HI ON OFF FLOW PRESSURE Step Up Transformer 120V 240V Laptop 19 LCD Monitor Power Up Sequence 1 Main 120V Supply ON 2 Transformer ON 3 Black Box On 4 Monitor ON 5 Laptop ON Critical Step Moni...

Страница 9: ...ower cord may be routed through the 2 diameter opening located in the back wall of the cabinet 3 The transformer Power On switch should be facing the front of the cabinet Plug A C power strip into the...

Страница 10: ...et on the upper right shelf Do not turn on the computer Follow the start up sequence on page 16 Setting up the Wireless Mouse 1 Be sure to plug in USB adapter for wireless mouse The adapter may be loc...

Страница 11: ...pump board 3 Connect to the pump by pushing the quick release metal tabs on the connectors at the pump when installing the tube ends 4 RED end goes to the HIGH pressure connector discharge BLUE goes t...

Страница 12: ...are found press the Stop Start button on the pump keypad tighten loose connections and resume start up 5 Turn the monitor ON Note Turn on monitor before turning on the computer 6 Turn the wireless mou...

Страница 13: ...First uninstall the current version to be sure you have latest software update 1 Click the Start menu lower right corner of tool bar and click Control Panel 2 Select Programs and Features 3 Select Pen...

Страница 14: ...the energy savings for a Standard vs IntelliFlo Variable Speed pump using the default values 4 To input your savings scenario click Click Here to Change Pool Description and follow the on screen instr...

Страница 15: ...on the selected pool size 6 To exit this screen and return to the 3 Meters Screen right click on the upper left corner of the screen 7 From the 3 Meter Screen there is also an informational video on t...

Страница 16: ...on set to 1440 x 900 resolution To switch between Calculator and pool size selection screen press Alt and Shift at the same time Demo kiosk shipments may include a flash drive with the latest software...

Отзывы: