P/N 619339
4
REV. G 4-23-1
2
11. With the inlet port of the fitting body in the 3 O’clock position, place the fitting body against the
threads of the flange and keeping the inlet port in the 3 O’clock position; see Figure 6. Hand tighten the
flange as tight as possible. Rotate the flange, not the body.
CAUTION
Do not over tighten the flange.
12. To complete the tightening process, hold the flange in place
and rotate the fitting body until the inlet port is in the 6
o’clock position; see Figure 6.
13. Take a hose clamp and place it over the return hose cuff.
14. Slip the return hose from the equipment, over the inlet port,
and tighten the hose clamp securely; see Figure 7.
15. Take the bulb assembly and insert it through the flow
director. Note the aligning keyway on the bulb assembly as
shown in Figure 8. The keyway must point in the same
direction as the top key on the fitting body.
16. Now, from inside the pool, push the bulb assembly and flow director with the red cap/plug in place into
the fitting body until the bulb assembly/flow director are nearly flush against the inside pool wall.
17. Thread the bulb assembly nut until it just touches the fitting body, then finger tighten.
CAUTION
Do not over tighten as adjustability of the flow director may be impaired and/or damage to parts
causing leakage may occur. If the flow director does not rotate by hand, the nut is too tight.
18. Take the red cap/plug off and gently bring the wire connectors through the back side of the bulb
assembly. Save the red cap/plug for storage and winterizing.
CAUTION
This lighting fixture may be damaged if subjected to
freezing weather. See winterizing instructions for details
on how to store the bulb assembly.
Inlet Port 3
O’clock
position
Body
Pool Wall
Wall
Flange
Liner
Gaskets (2)
Hose
Clamp
Figure 7.
6 O’clock
Figure 6.
Содержание AquaLuminator
Страница 1: ......