Install Drivers for 9000 Boards
11
640x480 - screen resolution (320x200, 640x480....etc)
S: - number of dots were received per second.
Pen - pen color
P: - the counter of received dots
D: - the counter of pen down
U: - the counter of pen up
(x,y) - current coordinate of dot
x:y: - minimum value of coordinate
X:Y: - maximum value of coordinate
3. Calibrate
Run the 'Calibrate' in PM2 Panel, and choose one of the 25 video
modes.
The purpose of calibration is to adjust the touch screen mapping to
meet the display screen properly.
You will be asked to select a video mode number. Select your display
mode by using keyboard to start calibration.
Touch the upper point, then touch the right point, bottom point and left
point, and press
<Enter>
key to pass the point. After calibration, the
calibrated data will be shown in the screen.
After calibration, we recommend you to do drawing test to verify the
touch screen and monitor mapped properly.
Function Keys:
[Enter]
- pass current point
[F9]
- camera, see above.
4. Detect
Detect PenMount automatically. You can press any key to abort the
detection.
Use the following list to detect PenMount:
COM1 (Base 03F8) (Baud 19200): IRQ 3, 4
COM2 (Base 03F8) (Baud 19200): IRQ 3, 4
COM3 (Base 03F8) (Baud 19200):
IRQ 3, 4, 5, 6, 7, 8, 9, 10, 11, 12,
13, 14, 15
COM4 (Base 03F8) (Baud 19200):
IRQ 3, 4, 5, 6, 7, 8, 9, 10, 11, 12,
13, 14, 15
COM1 (Base 03F8) (Baud 9600):
IRQ 3, 4
COM2 (Base 03F8) (Baud 9600):
IRQ 3, 4
COM3 (Base 03F8) (Baud 9600):
IRQ 3, 4, 5, 6, 7, 8, 9, 10, 11, 12,
13, 14, 15
COM4 (Base 03F8) (Baud 9600):
IRQ 3, 4, 5, 6, 7, 8, 9, 10, 11, 12,
13, 14, 15